• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1991 Fiscal Year Final Research Report Summary

The Improvement of Efficiency on the Microdissection in the SEM using Compound Materials : Its Development and Practice.

Research Project

Project/Area Number 02557068
Research Category

Grant-in-Aid for Developmental Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field Morphological basic dentistry
Research InstitutionHokkaido University

Principal Investigator

WAKITA Minoru  Hokkaido University, School of Dentistry, Professor, 歯学部, 教授 (40018916)

Co-Investigator(Kenkyū-buntansha) DOMON Takanori  Hokkaido Univ., Sch. of Dentistry, Assistant., 歯学部, 助手 (50217618)
YAMAMOTO Tsuneyuki  Hokkaido Univ. Sch. of Dentistry, Ass. Prof., 歯学部, 講師 (80200822)
Project Period (FY) 1990 – 1991
KeywordsSEM / Micromanipulator / Microdissetion / Compound material
Research Abstract

The grant for the studies on "the improvement of efficiency on the microdissection in the SEM using compound materials : Its development and practice" started just after the delivery of grant for 1991.
At first, the tip-instruments for microdissection were made by using tungsten-carbide-needle improved by us. They were sharpened by electrolysis and used for microdisection. At the same time the trial manufacture of new tip-instruments using metall-fibre-composit material started. The fibre materials, carbon fibre and silicon carbide fibre, were supplied from The Research Institute for Iron, Steel, and Other Materials, Tohoku University, ToRey Corporation, Nippon Carbon Co. The Berilium-Copper was finally selected as the metal to make composit material with these fibres. Because, this metal has relatively low melting point, 940C, and good physical constants. So it is very easy to treat in laboratory. Other metals tested for use, Cu, Pb, Sn, Zn, Al, were not sufficient in treatment and processign. The problem to use Be-Cu alloy was that this metal had not good intimacy to fibrous material to make wire made of composit material. This was shown in all the case of metals tested in the experiments.
These wire were etched by electrolysis and made to needle shaped tip instruments with 0.5mm thickness. These tip instruments could use only microdissection in low to medium magnification. Because, The sharpness and diameter of the needle was decided by the diametre of the single fiber. But these tip instruments had good hardness and stiffness to use for microdissection.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] 脇田 稔: "Structure and calcification of the enamel matrix of Paralichtys olivaceus." エナメル質比較発生学懇和会記録. 2. 13-16 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 脇田 稔,土門 卓文: "SEMにおけるマイクロマニピュレ-タの応用(微小解剖法)" SCAN TECH '92. 1. 99-100 (1992)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takano,Y.,Hanawa,M.,Domon,T.,Fujinami,H.,Hanaizumi,Y.and Wakita,M.: "Time-related changes in the distribution of ^<45>Ca in the developing enamel of rat incisor as revealed by autoradiography." J.Biol.Buccale. 18. 135-147 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takano,Y.,Yamamoto,T.,Domon,T.and Wakita,M.: "Histological,ultrastructural and electron microprobe analytical studies on the localization of caalcium in rat incisor ameloblastsa at early stage amelogenesis." Anat.Rec.25. 123-131 (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yamamoto,T.and Wakita,M.: "The development and structure of principal fibers and cellular cementum in rat molars." J.Periodontal Res.26. 129-137 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Domon,T.and Wakita,M.: "Electron microscopic and histochemical studies of the mononuclear osteoclast of the mouse." Am J.Anat.192. 35-44 (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Wakita, Minoru: "Structure and Calcification of the enamel matrix of Paralichtys olivaceus." Archives of Comparative Biology of Tooth Enamel.2. 13-16 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Wakita, Minoru and Domon, Takanori: "Micromanipulation in the SEM (Microdissection)." Scan Tech'92. 1. 99-100 (1992)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takano, Yoshiro, Hnawa, Masaaki, Domon, Takanori, Fujinami, Hiroyuki, Hanaizumi, Yosihiro and Wakita, Minoru.: "Time-related Changes in the Distribution of ^<45>Ca in the Developing Enamel of Rat Incisor As Revealed by Autoradiography." J. Biol. Buccale. 18. 135-147 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takano, Yoshiro, Yamamoto, Tsuneyuki, Domon, Takanori, and Wakita, Minoru.: "Hisotlogical, Ultrastructural, and electron microprobe analytical studies on the localization of calcium in rat incisor ameloblasts at early stage amelogenesis." Anat. Rec.25. 123-131 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yamamoto, Tsuneyuki and Wakita, Minoru: "The Development and Structure of Principal Fibers and Cellular Cementum in Rat Molars." J. Periodontal Res.26. 129-137 (1991)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Domon, Takanori and Wakita, Minoru: "Electron Microscopic and Histochemical studies of the Mononuclear Osteoclast of the Mouse." Am. J. Anat.192. 35-44 (1991)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1993-03-16  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi