1992 Fiscal Year Final Research Report Summary

Development of a system for measurement of bone mineral distribution patturn utilizing the dual energy subtraction technique

Research Project

Project/Area Number 02557078
Research Category

Grant-in-Aid for Developmental Scientific Research (B)

Allocation TypeSingle-year Grants
Research Field 外科・放射線系歯学
Research InstitutionTokyo Medical and Dental University

Principal Investigator

TSUGIHARA Katoh  Tokyo Med.&Dent.Univ., Fac.of Dent., Assistant, 歯学部, 助手 (70095107)

Co-Investigator(Kenkyū-buntansha) SEKITA Toshiaki  Tokyo Med.&Dent.Univ., Fac.of Dent., Assistant, 歯学部, 助手 (90236092)
ISHIDA Satoshi  Tokyo Med.&Dent.Univ., Fac.of Dent., Assistant, 歯学部, 助手 (00134734)
AKIBA Takashi  Tokyo Med.&Dent.Univ., Fac.of Med., Lecturer, 歯学部, 講師 (70184108)
KOBAYASHI Ken'ichi  Tokyo Med.&Dent.Univ., Fac.of Dent., Lecturer, 歯学部, 講師 (00170316)
SASAKI Takehito  Tokyo Med.&Dent.Univ., Fac.of Dent., Professor, 歯学部, 教授 (90013896)
Project Period (FY) 1990 – 1992
KeywordsBone mineral content / Dual energy subtraction / Digital image process / K-edge filtration
Research Abstract

(1) Construction of the system An image processing system was constructed using a laser film scanner and a work station, communicating with Ethernet network system. The system was able to input x-ray film images 1/6 cut size with 10 bit precision within 2min. including the image data transfer to the computer.
A software system previously developed on a personal computer based system, was implemented to the UNIX system. The user I/O was full GUI type constructed using Open window system, based on the Open Look standard, and most manupilation could be performed by the mous.
The system could output the quantitative bone minal content data of a pixel, the profile along a line which could be arbitrally defined, the projection in a given rectangle, and the integral in a given polygon. It took about 1 hour to process the image including the image scanning, which was longer than 15min. the purposed processing time of this project. The dominat factor of the processing time was sophisticated manup … More ilating procedure based on the user's judgment.
(2) Version up based on the trial use (Pacage for the indivisual application field) In order to simplify the procedure, the automatic recognition argorithm was introduced to the identification of the positions of steel ball merkers and the reference wedge. The ramp shaped reference wedge was replaced by a step wedge, which required less precission of the position. The ROI for the integration was also specifyed semi-automatically by the binarization of the target bone image. The processing time of the new version reduced to 30min. We found that the processing time reduced subatantially if an appropreate set of the predicted positions were given. We decided to develop pacages specialized to the application field, in which the shape and position of the reference wedge, film size and x-ray factors were fixed. Firstly, the gerodontic filed was chosen as the target of the prototype of the pacage, because the variation of the objects were expected to be small. We started the survay of the variation of the gerodontic objects. The pacage was expected to realize the purposed processing time within 15min. Less

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 加藤二久、小林賢一、水口俊介、片山圭一朗: "デュアルエネルギー差分法を用いた高空間分解能骨塩分布定量装置" J.Med.Electro.Biol.Engin.28(Suppl). 389- (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 加藤二久、小林賢一、水口俊介、長尾正憲: "デュアルエネルギー差分法に依る顎骨の骨塩量測定" 日本歯科補綴学会誌. 34(Suppl). 67- (1990)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Katoh,T.Sasaki: "Quantitative image by dual enevgy subtration in single exposure for measurement of bone mineral content" Med.Biol.Comput.Engin.29(Suppl). 912- (1991)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Katoh, K.Kobayashi, S.Minakuchi, M.Nagao, K.Katayama: "System for measurement of bone mineral distribution by high specific resolution with dual energy subtraction." J.Med.Electro.Biol.Engin.28(Suppl.). 389 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Katoh, T.Sakai, K.Kobayashi, S.Minakuchi, M.Nagao: "Measurement of bone mineral content in jaw using dual energy subtraction technique." J.Prothodont. 34(Suppl). 67 (1990)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Katoh, T.Sasaki: "Quantitative image by dual energy subtraction in a single exposrue for measurement of bone mineral content." Med.Biol.Engin.Comput.29(Suppl). 912 (1991)

    • Description
      「研究成果報告書概要(欧文)」より