1992 Fiscal Year Final Research Report Summary
STUDY ON THE DETERMINATION OF X-RAY EFFECTIVE ENERGY BY USING QUALITY INDEX
Project/Area Number |
03680198
|
Research Category |
Grant-in-Aid for General Scientific Research (C)
|
Allocation Type | Single-year Grants |
Research Field |
Nuclear engineering
|
Research Institution | KYOTO COLLEGE OF MEDICAL TECHNOLOGY |
Principal Investigator |
YAMADA Katsuhiko KYOTO COLLEGE OF MEDICAL TECHNOLOGY, RADIOLOGICAL TECHNOLOGY COURSE, ASSOCIATE PROFESSOR, 診療放射線技術学科, 助教授 (10230450)
|
Co-Investigator(Kenkyū-buntansha) |
FUJIMOTO Nobuhisa KYOTO COLLEGE OF MEDICAL TECHNOLOGY, RADIOLOGICAL TECHNOLOGY COURSE, LECTURER, 診療放射線技術学科, 講師 (10229049)
NISHITANI Motohiro KYOTO COLLEGE OF MEDICAL TECHNOLOGY, RADIOLOGICAL TECHNOLOGY COURSE, LECTURER, 診療放射線技術学科, 講師 (30228184)
|
Project Period (FY) |
1991 – 1992
|
Keywords | X-ray energy / X-ray spectrum / Radiation Dosimetry |
Research Abstract |
1.[Purpose of Research] : In case of using the medical X-ray apparatus, the measurement of X-ray effective energy can not carry out simply, because X-ray attenuation curve must be measured troublesome. Then, We considered a method which X-ray effective energy can be measured very simply by using a concept of Quality Index (QI). QI showing the distribution width of continuous X-ray spectrum is expressed by E_<eff> /E_<max>, where E_<max> is maximum energy of spectrum and E_<eff> is effective energy. From E_<max> is equal to value of X-ray tube voltage (kV), if QI values are prepared against various relating factors, X-ray effective energy can be determined easy by multipling QI by kV. In this research, many data of QI were produced for primary X-ray and scattered X-ray. 2.[QI measurement of primary X-ray] : The QI value depend on many X-ray quality factor, but in this research, QI measurements were carried out to following factor. (1) X-ray tube volt-age (50-150kV, 10kV step), (2) X-ray
… More
tube current (1, 100, 300mA), (3) high voltage wave form (single phase 2 peak type, inverter type, three phase 12 peak type, constant voltage type). 3.[QI estimation by spectrum] : The QI value for scattered X-ray can not be measured directry, because the measurement of attenuation curve for scattered X-ray are impossible. Then, a method which QI value is estimated by calculating from a scattered X-ray spectrum was investigated. And the spectrum were measured by a Ge-semiconductor detector. As result, both QI values of the expriment and the calculation agreed with high accuracy. Under this results, QI value for scattered X-ray were determined by the calculation using spectrum. 4.[QI estimation of scattered X-ray] : Using Ge-detector, the spectrum for scattered X-ray were measured against following factor. (1) X-ray tube voltage of primary X-ray (50-120kV , 10kV step), (2) volume of scattering material(1^3, 5^3, 20^3 cm^3 , Water and Acryl.), (3) scattering angle (30゚- 150゚, 30゚ step). The measured spectrums were converted to QI value by calculating respectively. Less
|