• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1993 Fiscal Year Final Research Report Summary

Pulse Operated MIP-MASS Sectroscopy

Research Project

Project/Area Number 04650041
Research Category

Grant-in-Aid for General Scientific Research (C)

Allocation TypeSingle-year Grants
Research Field 物理計測・光学
Research InstitutionSetsunan University

Principal Investigator

UCHIDA Teruo  Setsunan University, Faculty of Engineering, Professor, 工学部, 教授 (60029155)

Project Period (FY) 1992 – 1993
KeywordsMIP / Plasma / Spectrochemical Analysis / Excitation Temperature / Microwave Cavity / Electron Number Density / Finite Element Method / Atomic Emission Spectrometry / Spectroscopy
Research Abstract

In this work a new Microwave Induced Plasma(MIP) source with an axially-varied bore discharge tube was developed, whiche is able to introduce liquid aerosols directly into the plasma. The resonant frequency and electric field in the MIP TM010 cavity were calculated using the finite element method. The axially-varied tube highly enhanced the electric field on the edge an the center of the plasma discharge tube.
To confirm the effect of the discharge tube newly developed, the electron number density and the plasma temperatures were measured. The result shows that the density and the temperatures were both elevated. Accordingly, the calculation seems to be qualitatively adequate.
The measurements on plasma temperatures and on electron number density were made at a variety of operating conditions. Observed temperatures and electron number density exhibit significant increase, but decrease of argon emission intensity, upon the aqueous sample introduction. Experimental results suggest that local thermodynamic equilibrium is not consistent and excitation and ionization of atomic species due to collision with high energy elactron is dominant under the operating conditions employed for the measurements.
Using the new MIP source without cooling system, a stable plasma at relatively low forward microwave power (-20W) was obtained even with direct introduction of liquid aerosols. The effects of carrier gas flow rate, plasma gas flow rate and forward power on the intensity of Cd line were measured and the most suitable operating conditions were obtaind. To evaluate the new MIP as an excitation source for atomic emission spectrometry(AES), the linear dynamic range and the detection limits for several elements were also measured.

  • Research Products

    (4 results)

All Other

All Publications (4 results)

  • [Publications] 沖野晃俊、宮武健一郎、内田照雄、南茂夫: "ダブルボア放電管を持ったMIP共振器の解析" 分光研究. 42. 289-296 (1993)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 沖野晃俊、宮武健一郎、内田照雄、南茂夫: "ダブルボア放電管型MIP光源のプラズマ温度および電子密度の測定" 分光研究. 43. 23-30 (1994)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Akitoshi Okino, Ken-ichiro Miyatake, Teruo Uchida, Shigeo Minami: ""Analysis of an MIP Cavity with an axially-varied bore discherge tube"" J.Spectroscopical Soc.Japan. 42, No.5. 289-296 (1993)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Akitoshi Okino, Ken-ichiro Miyatake, Teruo Uchida, Shigeo Minami: ""Diagnostical Measurements of an Ar MIP Cavity with an axially-varied bore discherge tube"" J.Spectroscopical Soc.Japan. 43, No.1. 23-30 (1994)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1995-03-27  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi