1993 Fiscal Year Final Research Report Summary
A Study on Vibration Test with Noncontact Based on Magnetic Levitation
Project/Area Number |
04650210
|
Research Category |
Grant-in-Aid for General Scientific Research (C)
|
Allocation Type | Single-year Grants |
Research Field |
機械力学・制御工学
|
Research Institution | Chiba University |
Principal Investigator |
NONAMI Kenzo Chiba Univ., Faculty of Eng., Asso.Professor, 工学部, 助教授 (30143259)
|
Co-Investigator(Kenkyū-buntansha) |
NISHIMURA Hidekazu Chiba Univ., Faculty of Eng., Research Associate, 工学部, 助手 (70228229)
|
Project Period (FY) |
1992 – 1993
|
Keywords | Magnetic Levitation / Magnetic Bearing / Excitor without Contact / Three dimensional Excitor / Vibration Test / Bending Excitation / Torsional Excitation |
Research Abstract |
It is well known that there are major two vibration test method for structures. One is the sinsoidal and the random excitation method. The other is impulse excitation method. In these cases, actuators contac with test structures anytime. Therefore, it is difficult to measure the dynamic characteristics for moving structures in running and working like a rotating machinery in high speed rotations or a moving vehicle in high speed. This research work proposes a new concept and new strategy to measure dynamic characteristics for such moving structures. Namely, we verified that it is very useful for a three dimensional excitor with noncontact based on magnetic levitation to measure the dynamics of moving structures. This method will be also applied to rotating shaft in high speed rotation. We tried the following research works ; (1)The research work to develop the new hybrid actuators using permanent magnets and the electromagnets to save a energy, (2)The research work to realize the high stiffness between the controlled objects and the actuators, (3)The research works how to excite using actuators with high stability, (4)The research work to excite the three directions simultaneously. We have carried out the research work concerning above mentiond items. We concluded that it is possible to realize this new excitor with noncontact through the theoretical work and the experiments. Also, we will continue this research work to realize the actual test excitor.
|
Research Products