1994 Fiscal Year Final Research Report Summary
DEVELOPMENT OF CONTROL SYSTEM FOR THE FLOW RATE/PASSAGE OF TRITIUM WITH BREMSSTRAHLUNG COUNTING METHOD.
Project/Area Number |
05558066
|
Research Category |
Grant-in-Aid for Developmental Scientific Research (B)
|
Allocation Type | Single-year Grants |
Research Field |
Nuclear fusion studies
|
Research Institution | TOYAMA UNIVERSITY |
Principal Investigator |
MATSUYAMA Masao TOYAMA UNIVERSITY,HYDROGEN ISOTOPE RES.CENTER,ASSOC.PROF., 水素同位体機能研究センター, 助教授 (90135004)
|
Co-Investigator(Kenkyū-buntansha) |
SATO Hiroo ALOKA CO.LTD., RESEARCH INSTITUTE,MANAGER, 研究所, 部長
ASHIDA Kan TOYAMA UNIVERSITY,HYDROGEN ISOTOPE RES.CENTER,RES.ASSISTANT, 水素同位体機能研究センター, 助手 (70192953)
WATANABE Kuniaki TOYAMA UNIVERSITY,HYDROGEN ISOTOPE RES.CENTER,PROF., 水素同位体機能研究センター, 教授 (50001326)
|
Project Period (FY) |
1993 – 1994
|
Keywords | TRITIUM / FUEL CYCLE OF THERMONUCLEAR FUSION / BREMSSTRAHLUNG COUNTING METHOD / IN-SITU MEASUREMENT / NON-DESTRUCTIVE MEASUREMENT / BERYLLIUM WINDOW / MULTIPLE MATERIAL / FLOW CONTROL SYSTEM |
Research Abstract |
For tritium process in thermonuclear fusion reactors as well as a heavy water type reactor and the nuclear fuel reprocessing, it is indispensable to control the flow rate/passage of tritium according to the concentration of tritium. Especially, for the process of high level tritium, the development of precise control system for tritium is of a great importance from viewing point of safety. The applicability of a bremsstrahlung counting method to the insitu measurement of high level tritium has been examined so far. Since the penetration range of bremsstrahlung X-rays is remarkably greater than that of beta-rays, it is possible to measure directly the amount of tritium in a container attached with an appropriate window by the bremsstrahlung counting method. This method, therefore, will be a promising one to control the flow rate/passage of tritium. As a first step, to improve the sensitivity of bremsstrahlung counting method, the effect of a gold evaporated window on the intensity of bremsstrahlung X-rays has been examined. The window plays important roles of the confinement of tritium and the emission of the bremsstrahlung X-rays. By using the gold coating window, it was seen that the detection limit was extended toward lower tritium concentration of about 0.1 muCi/cm^3. In addition to the above examination, some preliminary experiments were carried out using an apparatus constructed to test the applicability of bremsstrahlung counting method to the control system. As a result, it was seen from the preliminary tests that two control valves attached to the present apparatus precisely operated at a given concentration irrespective to the flow rate in the range from 7 to 54 cm^3/min. From those results, it was revealed that it was possible to develop a tritium control system based on the bremsstrahlung counting method.
|
Research Products