1996 Fiscal Year Final Research Report Summary

Development of High Performance Micellar Chromatography for the Determination of Serum Aluminium

Research Project

Project/Area Number 07555564
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section試験
Research Field 工業分析化学
Research InstitutionTohoku University

Principal Investigator

YOTHUYANAGI Takao  Tohoku Univ., Fac.of Engineering, professor, 工学部, 教授 (00001199)

Co-Investigator(Kenkyū-buntansha) SATO Makoto  SHINO-TEST CORPORATION,Dep.of Research and Development, Reseacher, 研究開発部, 研究員
KANEKO Emiko  Tohoku Univ., Fac.of Engineering, Associate researcher, 工学部, 助手 (00241539)
HOSHINO Hitoshi  Tohoku Univ., Fac.of Engineering, Associate professor, 工学部, 助教授 (20124620)
Project Period (FY) 1995 – 1996
KeywordsAluminium / Serum / Micellar Chromatography / HPLC / 8-quinolinol
Research Abstract

A new method has been developed for the determination of serum aluminium with 8-quinolinol by kinetic defferenciation mode micellar chromatography. The proposed method with a semi-micro column and fluoremetric detection enabled the determination of aluminium down to 1 ppb in human serum without preliminary deproteinization. The most remarkable point of the method is that only aluminium ion selectively responses to this system. The complex formation of aluminium in serum with 8-quinolinol was completed within a few minutes at room temperature. The reaction mixture was applied to the chromatography directly. The serum matrix and aluminium chelate were separated on a reversed-phase column with an eluent containing 17% acetonitril, 0.01 M sodium dodecyl sulfate, 1 wt% TritonX-100, and 0.1 M N,N-Bis (2-hydroxyethyl) -2-aminoethanesulfonate buffer (pH 7.0). Then aluminium complex was detected with fluorescence detector (ex 370nm, em 504nm). There was good agreemnet between the values obtained by the proposed method and those by the Zeeman graphite-furnace absorption atomic spectrophotometry.

  • Research Products

    (8 results)

All Other

All Publications (8 results)

  • [Publications] Makoto Sato: "Determination of aluminium in human serum by kinetic differentiationon mode reversed phase micellar HPLC with fluorometric detection" Chemistry Letters. 203-204 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takao Yotsuyanagi: "“Kinetic differentiation mode"specific detection system for ultra trace aluminium by RP-HPLC and RP-HPTLC" Proceedings of 8th Russian-Japan Joint Symposium on Analytical Chemistry. 26-30 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 四ツ柳隆夫: "HPLCによる血清アルミニウムの簡易測定法" Medical Technology. 24. 882-884 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 佐藤 誠: "セミミクロ逆相分配カラムを用いる速度論的識別モード高性能ミセルクロマトグラフィーによる血清アルミニウムの定量法" 臨床化学. 25. 43-45 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Makoto Sato: "Determination of aluminium in homan serum by kinetic defferenciation mode reversed phase micellar HPLC with fluorometric detection" Chemistry Letter. 203-204 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takao Yotsuyanagi: "Kinetic defferenciation mode specific detection system for ultra trace aluminium by RP-HPLC and RP-HPTLC" Proceedings of 8th Russian-Japan Joint Symposium on Analytical Chemistry. 8. 26-30 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Takao Yotsuyanagi: "A simple method for the determination of serum aluminium by HPLC" Medical Techonology. 24. 882-884 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Makoto Sato: "Determination of serum aluminium by kinetic differenciation mode high performance micellar chromatography with semi-micro reversed phase partition column" Rinshokagaku. 25. 43-45 (1996)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1999-03-09  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI