1997 Fiscal Year Final Research Report Summary

Development of medical x-ray imaging system using semiconductor array for reduction of patient dose

Research Project

Project/Area Number 08557140
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Medical sociology
Research InstitutionFukui University of Technology

Principal Investigator

KANAMORI Hitoshi  Fukui University of Technology, Electrical Engineering, professor, 工学部, 教授 (70027770)

Co-Investigator(Kenkyū-buntansha) SATO Toshiyuki  Shimadzu Corporation, Basis Research Laboratory, chief scientist, 基盤研究所, 主任研究員
TAKIGAWA Atsushi  Hiroshima Prefectural College of Health and Welfare, Radiological Sciences and T, 助教授 (80197227)
KUBOTA Hideaki  Osaka University, Faculty of Medicine, research associate, 医学部, 助手 (30234496)
MATSUMOTO Masao  Osaka University, Faculty of Medicine, associate professor, 医学部, 助教授 (50149944)
NAKAMORI Nobuyuki  Kyoto Institute of Technology, Electronics and Information Science, associate pr, 工芸学部, 助教授 (20107353)
Project Period (FY) 1996 – 1997
Keywordsmedical x-ray image / semiconductor array / CdTe semiconductor detector / patient dose / image quality / anti-scatter grid
Research Abstract

(1)Using the traveling heat method for the crystal growth of CdTe semiconductor, uniformity and stability of semiconductor detector array were improved.
(2)Digital chest images were made using a CdTe semiconductor detector array having 3000 pixels. The spatial resolution was inferior compared with those made using screen-film systems, but the density resolution was superior. This suggests the utility of the compression of the dynamic range in the image processing.
(3)Measurements of x-ray spectra using a CdZn Te semiconductor detector system for 50-150kV and 25-35kV x-ray generators were performed.
(4)Factors of anti-scatter grids (the scatter ratio, the Bucky factor and the contrast improvement factor) were obtained from scatter and primary x-ray spectra.
(5)Small angle scattered spectra which were not removed by the gril were obtained. It was suggested that the small angle scatter could not be ignored.
(6)Tube voltage dependence of MTF's of screen-film systems were explained by the effect of scattered x rays. A new equation was proposed for thick screens, instead of Rossmann's equation

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] 佐藤 賢治: "マルチチャネルCdTe放射線検出器とその応用" 放射線. 22・3. 53-62 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 松本 政雄: "CdTe,TdZnTe検出器を用いて測定した診断用X線スペクトルの補正" 放射線. 22・3. 63-72 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] A.Takigawa: "Effects of antiscatter grid on x-ray spectram and radiographic" Journal of Photographic Science. 44・3. 93-98 (1996)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Matsumoto: "Direct measurement of mammographic x-ray spectra using CdZnTe detector" Medical Physics. 24・6. 1026 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] H.Kanamori: "Edge enhancement effect of radiographs" Medical & Biological Engineering & Computing. 35・S2. 1143 (1997)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] H.Arimura: "Comparison of Wiener spectra of quantum mottle for screen-film system with modnlation transfer functions" SPIE Proceedings. 3336(印刷中). (1998)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] K.Sato, S.Tokuda, S.Adachi, T.Inoue, M.Ukita, S.Ishida, T.Sato and M.Kiri: "Multichannel CdTe radiation detectors and applications" Ionization Radiation. 22[3]. 53-62 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Matsumoto, H.Kanamori, T.Toragaito and A.Taniguchi: "Correction of diagnostic x-ray spectra measured with CdTe and CdZnTe detectors" Ionization Radiation. 22[3]. 63-72 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] A.Takigawa, Y.Nishikawa, H.Kubota, Y.Ogata, M.Matsumoto and H.Kanamori: "Effects of anti-scatter grid on x-ray spectrum and radiographic contrast" Journal of Photographic Science. 44[3]. 93-98 (1996)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Matsumoto, H.Kanamori, A.Taniguchi and M.Yoshida: "Direct measurement of mammographic x-ray spectra using CdZnTe detector" Medical Physics. 24[6]. 1026 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] H.Kanamori, Y.Asai, Y.Ozaki, H.Kubota and M.Matsumoto: "Edge enhancement effect of radiographs" Medical & Biological Engineering & Computing. 35 Supplement Part 2. 1143 (1997)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] H.Arimura, T.Okawa, H.Kubota, M.Mataumoto and H.Kanamori: "Comparison of Wiener spectra of quantum mottle for screen-film system with modulation transfer functions" SPIE Proceedings. 3336(in press). (1998)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 1999-03-16  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi