• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2001 Fiscal Year Final Research Report Summary

Development of New type PET using liquid Xe scintillation light

Research Project

Project/Area Number 10305009
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section一般
Research Field Applied physics, general
Research InstitutionWaseda University

Principal Investigator

KIKUCHI Jun  Waseda Univ., Advanced Research Institute, Professor, 理工学総合研究センター, 教授 (50063665)

Co-Investigator(Kenkyū-buntansha) YAMAMOTO Mikio  National Institute of Radiological Sciences, Research Center for Charged Particle Therapy, Head of Special Research of Bio-Emission Laboratory, 室長 (80166826)
SUZUKI Satosi  Waseda Univ., Advanced Research Institute, Associate Professor, 理工学総合研究センター, 助教授 (30318828)
DOKE Tadayoshi  Waseda Univ., Honorary Professor, 理工学総合研究センター, 名誉教授 (60063369)
OKADA Hiroyuki  Waseda Univ., Advanced Research Institute, Assistant Professor, 理工学総合研究センター, 講師 (20308258)
MORI Toshinori  The University of Tokyo, International Center for Elementary Particle Physics Associate Professor, 素粒子物理国際研究センター, 助教授 (90220011)
Project Period (FY) 1998 – 2000
KeywordsLiquid Xe radiation detector / PET / Liquid noble gas radiation detector / Gamma ray detector / PMT for low temperature / Purification of noble gas / Scintillation of liquid noble gas
Research Abstract

Liquid Xe is transparent liquid with atomic number 54 and density about 3.0 g/cm^3. For gamma rays its scintillation efficiency is almost same as NaI(T1) and the decay time constants of scintillation, 2nsec and 22nsec, are much faster than that of NaI(T1). It is estimated that the high energy resolution will be obtained, by detecting direct light with a plural PMTs, without using the reflected light. Also it is possible to estimate the reaction position of the gamma ray by comparing the output from plural PMTs. By the simulation for the 0.5 MeV gamma ray, the position resolution of several mm was obtained with the good condition. Thereupon, we think the possibility of new-type PET using liquid Xe as detector medium and produced the liquid Xe detector and made to obtain the experimental data needed for PET development. The chamber is the cylinder forms of 2 layers and the outside layer is evacuated vacuously for heat insulation and detector part of PMTs is included in the inside layer. The inside layer is filled with liquid xenon and the detector part of 44 PMTs is set in it. The windows are the honey cam window made of the stainless steel of 500 μm thick at inside and the miler window of 100 μm thick at outside. The effective volume is 12X12X12 cm^3 that is surrounded with 44 PMTs of 1 inch and 2 inch. PMTs that we developed this time are 2 inch cylinder type(R6041-06MOD) and 1 inch rectangular type (R5900-06MOD) made by Hamamatsu Photonics company, and these hold the quartz window to have high transmission efficiency for vacuum ultraviolet light and is designed to act without any problem even with the low temperature (-110 ℃) and the high pressure (3atm). Also, it is made to decrease the outgas or the impurities that becomes the cause of the decrease of scintillation light. The position resolution is 7.8 mm and the time resolution is 0.69nsec. In the central part of effective volume, the energy resolution is 45 % for 511 keV gamma ray.

  • Research Products

    (11 results)

All Other

All Publications (11 results)

  • [Publications] T.Kato et al.: "Time and energy responses of liquid-xenon scintillation chamber for ^<20>Ne ion beam at 135A MeV"Jpn.J.Appl.Phys.. Vol.40. 3377-3381 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Tanaka et al.: "LET dependence of scintillation yields in liquid xenon"Nucl.Instr.And Meth.. A 457. 454-463 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 菊池順 他: "重イオンビームによる液体キセノンの発光効率の測定"1999 Annual report of the research project with heavy ions at NIRS-HIMAC. 258-259 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] H.Okada et al.: "Liquid Xe homogeneous electro-magnetic calorimeter"Nucl.Instr.And Meth.. A 451. 427-438 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Kato et al.: "Scintillation yield in liquid argon for non-relativistic protons and helium ions"Nuclear Instruments and Methods. A 433. 619-622 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] K.Terasawa et al.: "New UV-sensitive photomultiplier (R6041Q) for direct detection of liquid xenon scintillation light"Advanced Research Institute for Science and Engineering, Technical Report. No.98-12. 1-22 (1998)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T. Kato, T. Doke, J. Kikuchi, F. Nishikido, H. Okada, K. Morimoto and I. Tanihata: "Time and energy responses of liquid-xenon scintillation chamber for 20Ne ion beam at 135A MeV"Jpn. J. Appl. Phys.. Vol. 40. 3377-3381 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Tanaka, T. Doke, A. Hitachi, T. Kato, J. Kikuchi, M. Masuda, T. Murakami, F. Nishikido, H. Okada, E. Shibamura and E. Yoshida: "LET dependence of scintillation yields in liquid xenon"Nuclear Instruments and Methods in Physics Research A. 457. 454-463 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] H. Okada, T. Doke, T. Kashiwagi, J. Kikuchi, M. Kobayashi, K. Masuda, E. Shibamura, S. Suzuki, T. Takashima and K. Terasawa: "Liquid Xe homogeneous electro-magnetic calorimeter"Nuclear Instruments and Methods in Physics Research A. 451. 427-438 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T. Kato, T. Doke, J. Kikuchi, K. Masuda, K. Ozaki, E. Shibamura and M. Tanaka: "Scintillation yield in liquid argon for non-relativistic protons and helium ions"Nuclear Instruments and Methods in Physics Research Sect. A. (433) 3. 619-622 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Terasawa, T. Doke, J. Kikuchi, Y. Kuno, A. Maki, T. Mashimo, K. Masuda, T. Miyazawa, T. Mori, H. Okada, S. Orito, Y. Sugimoto, S. Takenaka, S. Tanaka, M. Yamashita and K. Yoshimura: "New UV-sensitive photomultiplier (R6041Q) for direct detection of liquid xenon scintillation light"Advanced Research Institute for Science and Engineering, Technical Report. No.98-12. 1-22 (1998)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2003-09-17  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi