• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

1999 Fiscal Year Final Research Report Summary

A STUDY OF SIGNAL PROCESSING FOR CAPACITANCE SENSORS USING SWITCHED-CAPACITOR CIRCUITS

Research Project

Project/Area Number 10650421
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Measurement engineering
Research InstitutionSUZUKA NATIONAL COLLEGE OF TECHNOLOGY

Principal Investigator

KONDO Kazuyuki  SUZUKA NATIONAL COLLEGE OF TECHNOLOGY, ASSOCIATE PROFESSOR, 電気工学科, 助教授 (00170423)

Project Period (FY) 1998 – 1999
KeywordsCAPACITANCE SENSOR / SENSOR SIGNAL PROCESSING / SWITCHED-CAPACITOR CIRCUIT
Research Abstract

The purpose of this study is to develop signal processing circuits for capacitance sensors using switched-capacitor circuits.
First, a novel switched-capacitor bridge is developed for high accuracy and high speed capacitance measurements. Its principle of operation is based on the two-step quantization of the capacitance under measurement. The first step of measurement is a coarse quantization, which corresponds to the main scale, performed by the charge-balancing M-bit analog-to-digital (A/D) converter. The second step is a fine quantization to interpolate the quantization error of the first step into K bits. This interpolation, which corresponds to the vernier scale, is performed by the single-slope A/D converter. The total resolution is M+K bits. A prototype bridge using discrete components has confirmed the principles of operation.
For high-accuracy signal processing of differential capacitance sensors, an interface circuit based on a switched-capacitor sample/hold circuit is develop … More ed. Driven by nonoverlapping two-phase clocks, the interface produces the output voltage which is proportional to the ratio of difference-to-sum of two capacitors of a differential sensors. Spice simulations show that 0.1% resolution is easily achievable with the simple configuration. Experimental results are given to confirm the simulations.
Furthermore, a time-domain method for measuring circuit parameters of RLC and active filter circuits is presented. The principle is based on the oscillatory response to a step excitation. A digital oscilloscope is used to observe the step response. Receiving data thus acquired via the RS-232 interface, a computer calculates required parameters. Accuracy estimates show that the measurement error is less than 2 percent when an oscilloscope with an 8-bit resolution is used. Experimental results are given to confirm the principles of measurement and accuracy estimates.
Fabrication process of the switched-capacitor circuits compatible with IC sensors is best suited for the built-in interface of intelligent capacitance sensors. Less

  • Research Products

    (8 results)

All Other

All Publications (8 results)

  • [Publications] Kenzo WATANABE: "A Switched-Capacitor Interface for Differencial Capacitance Transducers"Proceeding of the 16th IEEE Inatumentation&Measurement Technology Conference(Venice, Italy). Vol.1. 315-319 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Satomi OGAWA: Proceeding of 1999 International Technical Conference on Circuits/Systems, Computers and Communications(Sado, Japan). 1072-1075 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuyuki KONDO: "Resonant Q Measurement Using a Digital Oscilloscope"Fourth International Conference on Measurement and Instruments Conference Proceedings(Harbin, China). Vol.1. 35-38 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 近藤一之: "副尺の概念に基づいたスイッチトキャパシタキャパシタンスブリッジ"鈴鹿工業高等専門学校紀要. 第33巻. 39-43 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] KENZO WATANABE: "A Switched-Capacitor Interface for Differential Capacitance Transducers"Proceedings of the 16th IEEE Inatumentation & Measurement Technology Conference (Venice, Italy). 1. 315-319 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] SATOMI OGAWA: "A Switched-Capacitor Interface for High-Accuracy Signal Processing of Differential Capacitance Transducers"Proceedings of 1999 International Technical Conference on Circuits/Systems, Computers and Communications (Sado, Japan). 1072-1075 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] KAZUYUKI KONDO: "Resonant Q Measurement Using a Digital Oscilloscope"Fourth International Conference on Measurement and Instruments Conference Proceedings (Harbin, China). 1. 35-38 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] KAZUYUKI KONDO: "A Switched-Capacitor Capacitance Bridge Based on the Vernier Scale Concept"Memoirs of Suzuka National College of Technology. 33. 39-43 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 