• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2000 Fiscal Year Final Research Report Summary

Development of Radiological Diagnostic Information System for Dental Practice Based on DICOM-3.0

Research Project

Project/Area Number 10671765
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 病態科学系歯学(含放射線系歯学)
Research InstitutionTokyo Metropolitan University of Health Sciences

Principal Investigator

KATOH Tsuguhisa  Tokyo Metropolitan University of Health Sciences, Radiologic Science, Associate Professor, 保健学部, 助教授 (70095107)

Co-Investigator(Kenkyū-buntansha) OHBAYASHI Naoto  Tokyo Medical and Dental University, Graduate School, Assistant, 歯学部, 助手 (40176988)
NEGISHI Tohru  Tokyo Metropolitan University of Health Sciences, Radiologic Science, Assistant, 保健学部, 助手 (00259144)
SAITOH Hidetoshi  Tokyo Metropolitan University of Health Sciences, Radiologic Science, Associate Professor, 保健学部, 助教授 (50196002)
Project Period (FY) 1998 – 2000
KeywordsDental Radiology / Picture Archive and Communication System (PACS) / Radiological Information System (RIS) / DICOM Standard / Medical Informatics
Research Abstract

(1) Harmonization of Diagnostic Image in Dental and Oral Radiology to DICOM Supplement 32
Attributes of intaoral radiography and panoramic radiography were analyzed by Object Oriented Analysis. It was found that attribute definitions in DICOM Supplement 32 lacked in attributes for CR images and Secondary Caputre(SC) images.
(2) Development of CTN image storage server using Oracle8 as the database engine
In order to manage a large number of images, CTN software was modified to apply Oracle8 database engine. Using it, a DICOM image server/client system was constructed for research and education.
(3) Simulation of DICOM object of intraoral radiography
A sample object of intraoral radiography was created for convenience of software development, which included all the attributes defined in Supplement 32.
(4) DICOM object of MRI moving image for tmpolomandibular joint diagnosis
A DICOM SOP class was defined for moving image using Quick algorithm software for the compression. A software system was developed to create objects and display the moving image.
(5) Automatic secondary capturing system for film based intraoral radiography
A SCU software for image storage SOP Class was developed for the effective input of film based intraoral radiography.

  • Research Products

    (12 results)

All Other

All Publications (12 results)

  • [Publications] T.Katoh,H.Saitoh, et.al.: "Application of DICOM Supplement 32 to Computed Radiography and Digitized Film Image"Japanese Journal of Medical Physics. Suppl.57. 204-207 (1998)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Katoh,H.Saitoh, et.al.: "A Supplementation to DICOM Supplement 32 (DIgital X-ray) for Digitized Film and Compated Radiography"Proceeding of SPIE. 3662. 369-376 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Y.Nomura,T.Katoh,T.Negish, et.al.: "Construction of DICOM Server using Orocle and STN foftware"Japanesae Jouranl of Medical Physics. Suppl.61. 309-310 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 野村行弘,加藤二久,斎藤秀敏 他: "東京都立保健科学大学における教育・研究用DICOMネットワークの構築について"東京保健科学学会誌. 2(4). 300-305 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Negishi,T.Katoh,M.Fukushi et.al.: "Adaptation to DICOM-3.0 of the Jaw Joint Movement Image"Proceedings of SPIE. 3980. 429-436 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Katoh,T.Sasaki,H.Kotani, et.al.: "Oral and Maxillofacial Radiology Today pp129-131"Elseviver Science, Amsterdam. 655 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 佐々木武仁,加藤二久 他: "ディジタル投影X線画像データフォーマット(DICOM3.0,2000)実装ガイドライン-歯科領域を中心に-"(財)医療情報システム開発センター/IS&C委員会(出版予定)(未定). (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Katoh, H.Saitoh, M.Matsumoto, N.Ohbayashi, T.Sasaki: "Application of DICOM Supplement32 to Computed Radio-graphy and Digitized Film Image."Jap.Jurn, Med.Phys.Suppl.. 57. 204-207 (1998)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Katoh, H.Saitoh, M.Matsumoto, N.Ohbayashi, T.Sasaki, S.Shimanishi: "A supplementation to DICOM Supplement 32 (Digital X-ray) for digitized film image and computed radiography."Proc.SPIE. 3662. 369-376 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y.Nomura, T.Katoh, H.Saitoh, T.Negishi, A.Senoo, S.Shimanishi, N.Ohbayashi: "Construction of DICOM server using Oracle and CTN software."Jap.Jurn.Med.Phys.suppl.. 61. 309-310 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Negishi, T.Katoh, M.Fukushi, A.Senoo., Y.Nomura, S.Shimanishi: "Adaptation to DICOM-3.0 of the jaw joint movement image."Proc. SPIE. 3980. 429-436 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Katoh, T.Sasaki, H.Kotani, H.Saitoh, T.Negishi, N.Ohbayashi, E.Honda: "A Digitizing and Filing System of Film Based Intraoral Radiography."Oral and Maxillofacial Radiology Today. Elsevier Science Amsterdam. 129-131 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2002-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi