• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2001 Fiscal Year Final Research Report Summary

The development and evaluation of super high resolution MR microscopy.

Research Project

Project/Area Number 11470187
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionNational Institute of Radiological Sciences

Principal Investigator

IKEHIRA Hiroo  National Institute of Radiological Sciences, Dep.Medical Imaging, Head, 医学物理部, 室長 (50150313)

Co-Investigator(Kenkyū-buntansha) TANADA Shuji  National Institute of Radiological Sciences, Dep.Medical Imaging, Director, 医学物理部, 部長 (40116950)
SUHARA Tetsuya  National Institute of Radiological Sciences, Dep.Medical Imaging, Director, 医学物理部, 特別上席研究員 (90216490)
OSUGA Toshiaki  Chiba University, School of Science, Assistant Professor, 理学部, 助手 (80223816)
IRIE Toshiaki  National Institute of Radiological Sciences, Dep.Medical Imaging, Head, 医学物理部, 室長 (40160072)
MURAYAMA Hideo  National Institute of Radiological Sciences, Dep.Medical IPhysics, Head, 医学物理部, 室長 (50166310)
Project Period (FY) 1999 – 2001
KeywordsNMR / MR microscopy / MRI / special resolution / pulse sequence
Research Abstract

It suited pursuing resolution between the high-spatial-resolution of the performance limit in 1999 using the gradient coil of MRI for research of currently possessed, and a highly efficient through rate. Between the high-spatial-resolution of the first year, the concrete achievement target of resolution should be 50 micrometers and the target of the 1st phase was the creation of the spin echo method pulse sequence for achievement and the small volume coil aiming at mouse size are made as an experiment The possibility of resolution was experimentally examined between the further high-spatial-resolution from the result of the S/N measurement and the picture using such hard software. In 2000, high resolution imaging in the equipment for clinical of 1.5T, hybrid equipment was manufactured and adjustment and a check of the practicality were performed the highest of the picture which made the homemade coil for a saddle type MR microscopy and was obtained in the last year using the coil, and the result which resolution became about 30 microns per pixel, and exceeded far the prospective target value of 100 to 50 microns was obtained This resolution is considered from S/N expected by 1.5T, and is presumed to be almost close to a theoretical marginal value. However, high spatial resolution MR image, many problems which contrast, S/N and vibration, and a photographic subject should motion-etc.-solve are left behind future with the equipment for clinical of 1.5T, high spatial resolution by enforcing the optimal pulse sequence for imaging examines the possibility of clinical application furthermore, between the resolution obtained using development of a highly efficient high sensitivity probe, simultaneously pathology data, etc. It is thought that it is necessary perform comparison examination with an high resolution MRI picture and to perform clinical technical evaluation in parallel

  • Research Products

    (8 results)

All 2002 2001 2000 1999

All Journal Article (7 results) Book (1 results)

  • [Journal Article] The measurement of the electrical properties of human skin and the variation among subjects with certain skin conditions.2002

    • Author(s)
      Ikehira H et al.
    • Journal Title

      Phys.Med.Biol 47

      Pages: N11-N15

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] ong-term assessment of post-transplant renal prognosis with 31P magnetic resonance spectroscopy.2001

    • Author(s)
      Ikehira H et al.
    • Journal Title

      Transplantation 72

      Pages: 627-630

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] ong-term assessment of post-transplant renal prognosis with ^<31>P magnetic resonance spectroscopy.2001

    • Author(s)
      Ikehira H et al.
    • Journal Title

      Transplantation 72

      Pages: 627-630

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Seizure frequency and bilateral temporal abnormalities : a proton magnetic resonance spectroscopy of temporal lobe epilepsy.2000

    • Author(s)
      Ikehira H et al.
    • Journal Title

      Seizure 9

      Pages: 274-279

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] The preliminary study for clinical pharmacokinetics of oral fluorine anticancer medicines using commercial MRI system ^<19>F-MRS.1999

    • Author(s)
      Ikehira H et al.
    • Journal Title

      British Journal of Radiology 72

      Pages: 584-589

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Perfusion recovery after lung volume reduction surgery.1999

    • Author(s)
      Watanabe N, Tanada S et al.
    • Journal Title

      Clin.Nucl.Med. 24

      Pages: 619-621

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Positron emission tomographic measurement of acetylcholinesterase activity reveals differential loss of ascending cholinergic systems In Parkinson's disease and progressive supranuclear palsy.1999

    • Author(s)
      Shinotoh H, Tanada S et al.
    • Journal Title

      Ann.Neurol. 46

      Pages: 62-69

    • Description
      「研究成果報告書概要(和文)」より
  • [Book] MRI/MRSによる診断-MRIはどうして画になるのか-2000

    • Author(s)
      池平博夫
    • Total Pages
      114-117
    • Publisher
      医療科学社
    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2006-07-11  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI