Continuous flow artificial heart and adaptation of living body

Research Project

Project/Area Number 11557096
Research Category

Grant-in-Aid for Scientific Research (B).

Allocation TypeSingle-year Grants
Section展開研究
Research Field Thoracic surgery
Research InstitutionUniversity of Tsukuba

Principal Investigator

TSUTSUI Tatsuo  Institute of Clinical Medicine, University of Tsukuba Associate Professor, 臨床医学系, 助教授 (50112868)

Co-Investigator(Kenkyū-buntansha) SANKAI Yoshiyuki  Mechanics & Systems Institute of Engineering, University of Tsukuba Associate Professor, 機能工学系, 助教授 (30183833)
SHIGETA Osamu  Institute of Clinical Medicine, University of Tsukuba Associate Professor, 臨床医学系, 講師 (10196371)
JIKUYA Tomoaki  Institute of Clinical Medicine, University of Tsukuba Associate Professor, 臨床医学系, 講師 (20231368)
Project Period (FY) 1999 – 2000
Keywordscontinuous flow artificial heart / mono-pivot / flow visualization / adaptation physiology / autonomic nervous system / remote monitoring / remote control / telemetry
Research Abstract

The purposes of this study are the development of continuous flow artificial heart, the evaluation of the adaptation status of living bodies to continuous flow circulation, and the development of remote monitoring and control system for living bodies with artificial hearts.
For the determination of antithrombogenic design of continuous flow artificial heart, we adopted flow visualization method and animal experiments using 9 sheeps. The comparison of results of flow visualization study and anmal experiments show good correlation on the sites of thrombi formation. This strategy shortened the duration of investigation for optimal design of the continuous flow artificial heart.
As a fundamental research, activities of autonomic nervous system was evaluated using power spectrum analysis of arterial pressure waves in clinical cases with mechanical circulatory support including continuous flow blood pumps. The low frequncy (0.04-0.15Hz) values representing sympathetic nerve actoivities were hi … More ghly depressed in cases with poor clinical outcome. In animal experiments with continuous flow artificial heart, the low frequency values of arterial pressure power spectra were not depressed and those were stable during phalmacological arterial pressure perturbation. It means the sufficient adaptation of animals for addition of continuous flow circulation
Systems for remote monitoring of the animal with artificial heart and for remote control of the artificial heart were developed. Continuous monitoring of parameters including arterial and venous pressures, blood flow, body temperature. pump rotatioraal speed and energy consumption of the pump were able to be performed using World Wide Web. Moving photographs of the animals were also transmitted via Web. The remote control of pump rotational speed was successfully conducted also via the home page protected by passwords.
By application of the results of these studies, it becomes possible to continue more efficient and reliable research for the clinical application of continuous flow artificial heart for patients with severe circulatory disorders. Less

  • Research Products

    (14 results)

All Other

All Publications (14 results)

  • [Publications] Tsutsui,Tatsuo: "Evaluation of stress on the autonomic nervous system of patients on mechanical circulatory assist"International Journal of Artificial Organs. 24(1). 47-51 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tsutsui,Tatsuo: "Sympathoinhibition in critical illness during mechanical circulatory support"ASAIO Journal. 46(2). 197-197 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Sankai,Yoshiyuki: "Bio-telemetry system and non-invasive sensors for smart artificial heart (SAH)"ASAIO Journal. 46(2). 205-205 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Yamane,Takashi: "Design enhancement for antithrombogenicity of a monopivot magnetic suspension blood pump"Proceedings of the 7th International Symposium on Artificial Heart & Assist Devices. 30-30 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tsutsui,Tatsuo: "Power spectral analysis of arterial pressure signals during mechanical circulatory support"Artificial Organs. 23(7). 625-625 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Maruyama,Osamu: "A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs"Artificial Organs. 23(3). 274-279 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tsutsui,Tatsuo: "Idioperipheral Pulsation During Nonpulsatile Circulation in "Rotary Blood Pumps."; H.Matsuda(ed)"Springer-Verlag Tokyo. 125 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Tsutsui, Tatsuo: "Evaluation of stress on the autonomic nervous system of patients on mechanical circulatory assist"International Journal of Artificial Organs. 24 (1). 47-51 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Tsutsui, Tatsuo: "Sympathoinhibition in critical illness during mechanical circulatory support"ASAIO Journal. 46 (2). 197-197 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Sankai, Yoshiyuki: "Bio-telemetry system and non-invasive sensors for smart artificial heart (SAH)"ASAIO Journal. 46 (2). 205-205 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Yamane, Takashi: "Design enhancement for antithrombogenicity of a monopivot magnetic suspension blood pump"Proceedings of the 7th International Symposium on Artificial Heart & Assist Devices. 30-30 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Tsutsui, Tatsuo: "Power spectral analysis of arterial pressure signals during mechanical circulatory support"Artificial Organs. 23 (7). 625-625 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Maruyama, Osamu: "A preliminary study of microcapsule suspension for hemolysis evaluation of artificial organs"Artificial Organs. 23 (3). 274-279 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Tsutsui, Tatsuo: "Idioperipheral Pulsation During Nonpulsatile Circulation"in "Rotary Blood Pumps." ; H.Matsuda (ed), Springer-Verlag Tokyo. 21-34 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2002-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI