• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2000 Fiscal Year Final Research Report Summary

New development of compact tensile tester with scanning probe microscope for micro-scale specimen

Research Project

Project/Area Number 11650107
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Materials/Mechanics of materials
Research InstitutionRitsumeikan University

Principal Investigator

TANAKA Takeshi  Ritsumeikan Univ., Fac.Science and Engineering, Professor, 理工学部, 教授 (10029209)

Co-Investigator(Kenkyū-buntansha) ISONO Yoshitada  Ritsumeikan Univ., Fac.Science and Engineering, Associate Prof., 理工学部, 助教授 (20257819)
Project Period (FY) 1999 – 2000
KeywordsScanning probe microscope / Tensile test / Single crystal silicon / Young's modulus / Fracture strength / Micro machining / Thin film
Research Abstract

This research describes a micro-scale tensile test with a scanning probe microscope (SPM) for micro-scale materials used in electronic and MEMS devices. Three kinds of materials, which are single crystal silicon (Si), diamond like carbon and permalloy thin films, was used here. The film specimens were fabricated by a micro machining process technique. A compact tensile tester including a smaller sized piezoelectric actuator was also newly developed, and the tester was built in the SPM.It has been so far difficult to measure strain of micro-scale specimen during a tensile test because of the shorter gage length of specimen. In this research, the SPM was used as an extensometer of micro-scale specimens with a resolution on the order of 1 nanometer, so that strain was obtained in the course of tests.
Young's modulus of micro-scale Si specimen measured by the SPM ranged from 157 GPa to 166 GPa, which was similar to that of millimeter scale Si. Furthermore, the Young's modulus of Si recalculated by fitting the SPM data to a spline function showed 170 GPa, which was in agreement with that of bulk sized Si in [110] direction. The micro-scale specimen produced an increase of the tensile strength since the strength of micro-scale Si specimen showed 0.9-1.2 GPa that was 2-3 times larger than that of bulk sized Si. Scanning electron microscopic observations also revealed micro-scale Si specimen fractured brittle manner in room temperature. So, the specimen size effect on tensile strength would have been caused by a reduction of the number of cracks in specimen with decreasing the specimen size.
This research also carried out tensile tests of DLC and permalloy thin films deposited on the micro-scale Si specimen. However, an accurate stress-strain curve of DLC and permalloy films was not obtained since the film specimen did not fractured at the gage part of specimen. Further experiments are needed to reveal mechanical properties of DLC and permalloy films.

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] Takahiro Namazu, Yoshitada Isono and Takeshi Tanaka: "Evaluation of Size Effect on Mechanical Properties of Single Crystal Silicon by Nano-Scale Bending Test using AFM"Journal of Micro Electro Mechanical Systems, IEEE. Vol.9,No.4. 450-459 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Takahiro Namazu, Yoshitada Isono and Takeshi Tanaka: "Evaluation of Size Effect on Mechanical Properties of Single Crystal Silicon by Nano-Scale Bending Test using AFM"Journal of MEMS, IEEE. Vol.9, No.4. 450-459 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2002-03-26  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI