Dosimetry of interstitial brachytherapy sources using new thermolumionescent sheet

Research Project

Project/Area Number 11670908
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionNara Medical University

Principal Investigator

IWATA Kazuro  Nara Medical University, Department of Oncoradiology, Assistant Professor, 医学部・腫瘍放射線医学教室, 講師 (00201343)

Project Period (FY) 1999 – 2000
Keywordsbrachytherapy / dosimetry / radioactive source / TL sheet
Research Abstract

In order to measure the spatial dose distribution in the immediate vicinity of brachytherapy sources, we have newly developed a wide and high-resolution themoluminescent (TL) sheet, which is a teflon homogeneously mixed with small powders of thermoluminescent BaSO_4 : Eu doped, and its spatial dose distribution readout system.
In this work, the spatial resolution and accuracy of this TL sheet were investigated.
1. The spatial resolution of the TL sheet was 62μm corresponding to 8.1 line pairs/mm. Also, the spatial resolution was 13 line pairs/mm measured at the 5% level of the modulation transfer function. This suggests that TL sheet is useful to measure the spatial dose distribution near in the radiation field with large dose gradients over small area.
2. With brachytherapy sources I-125 (Model 6711 and Model 6702), and Pd-103 (Model 200) of low energy photon emitters , the radial dose functions and anisotropy constants with TL sheet were agreed well with those with LiF-TLD.Anisotropy functions on brachytherapy sources could easily be mapped using TL sheet. Also, anisotropy functions were symmetric on the long axes of sources, and clearly delineated the dosimetric characteristics of the source edges.
3. As a result, this high resolutional TL sheet may provide a convenient and accurate means of measuring the dose distribution near brachytherapy sources, because the TL sheet has been found to have a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy absorbed dose.

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 岩田和朗: "TL-シートによる重粒子線ビームプロファイルの測定"平成10年度放医研共同利用研究報告書. NIRS-M133. 241-242 (1999)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 岩田和朗: "TLDによるBragg peak近傍の2次元線量分布測定"平成11年度放医研共同利用研究報告書. NIRS-M139. 222-223 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] K.Iwata: "Dynamical model for the growth and size distribution of multiple metastatic tumors."J.theor.Biol.. 203. 177-186 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] K.Iwata, I.Yamamoto, M.Nakagawa, et al: "Measurements of heavy particle beam profiles with TL-sheets."1998 Annual Report at NIRS-HIMAC. NIRS-M-133. 241-242 (1999)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K.Iwata, I.Yamamoto, M.Nakagawa, et al: "Measurements of 2-dimensional dose distributions near Bragg peak with TLDS."1999 Annual Report at NIRS-HIMAC. NIRS-M-139. 222-223 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K.Iwata, K.Kawasaki, N.Shigesada: "Dynamical model for the growth and size distribution of multiple metastatic tumors."J.theor.Biol.. 203. 177-186 (2000)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2002-03-26  