• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2002 Fiscal Year Final Research Report Summary

A Study on Automation and Simplification in Endodontics

Research Project

Project/Area Number 12307042
Research Category

Grant-in-Aid for Scientific Research (A)

Allocation TypeSingle-year Grants
Section一般
Research Field Conservative dentistry
Research InstitutionTokyo Medical and Dental University

Principal Investigator

KOBAYASHI Chihiyo  Tokyo Medical and Dental Unversity, Associate Professor, 大学院・医歯学総合研究科, 助教授 (80126226)

Co-Investigator(Kenkyū-buntansha) KOBAYASHI Kenji  Meikai University, Dental School, Lecturer, 歯学部, 講師 (20170318)
KOMORI Nirio  Nihon Unversity, Dental School, Lecturer, 歯学部, 助手 (60153681)
NAGAI Oosuke  Kanagawa Dental School, Leturer, 講師 (10121021)
NAKAJIMA Masato  Asahi University, Dental School, Lecturer, 歯学部, 講師 (50113048)
IIDA Kouju  Tokyo Medical and Dental University, Assistant Professor, 大学院・医歯学総合研究科, 助手 (00291344)
Project Period (FY) 2000 – 2002
Keywordsnickel-titanium file / hand muscle activity / double-injection method / reflected light power spectrum / dental CCD camera / bleaching of teeth / root canal irrigation
Research Abstract

1. Load and torque generated during preparation were measured. Race nickel-titanium files showed smaller torque than Profiles (Kobayashi C.).
2. In the combination of 7 kinds of nickel-titanium files and 4 kinds of handpieces, plastic tooth models were prepared. Little difference regarding the preparation time was observed between nickel-titanium files and hand stainless files (Nagai).
3. Compositions of 7 kinds of nickel-titanium files were analyzed. There was negligible difference concerning the ratio of Ni to Ti (Kobayashi K.).
4. New root canal preparation device working with the Apit was developed (Komori).
5. In the preparation of curved canals with nickel-titanium files, useful suggestions were obtained (Iida).
6. Tuck-Endo nickel-titanium files showed good properties in curved canals (Shoji).
7. Using a 200 μm fiber, slightly curved canals could be prepared with the Nd : YAG laser (Nakajima).
8. Heating less than 400 ℃ and 1 hour, did not change the mechanicai propertics of stainless K files (Kaya).
9. The characteristics of RT files were studied (Tsuzuki).
10. Hand muscle activities during root canal preparation were studied (Ozawa).
11. Contamination of the root canal was measured with power spectrum of the reflected light (Ikawa).
12. Root canal walls were observed using a fiber scope (Takashiba).
13. Sterilizing power of various irrigation methods were compared (Takenaka).
14. Bleaching with TiO2 catalyst and H2O2 was studied (Tanaka).

  • Research Products

    (6 results)

All Other

All Publications (6 results)

  • [Publications] 小林千尋, 吉岡隆知他7名: "根管形成時にファイルに加わる応力の動的観察"日歯保存誌. 45. 1044-1048 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Ozawa, T., Nakano, M.他4名: "Effects of endodontic instrument handle diameters on electromyographic activities of forearm and hand muscles"International Endodontic Journal. 34. 100-106 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 杉村博行, 小澤寿子他5名: "根管拡大時のファイルハンドル径と手首の角度の手腕筋筋活動への影響"日歯保存誌. 45. 216-222 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 吉田達雄, 庄司 茂, 堀内 博, 島内英俊: "ニッケルチタンファイル:タックエンドファイルの拡大能力評価"日歯保存誌. 45. 657-664 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 中嶋正人, 平田健一, 今井 潔, 関根一郎: "Nd : YAGレーザーを用いた根管形成の可能性について 第1報 直線根管への応用"日歯保存誌. 45. 977-983 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 小林賢一, 小林賢一, 田上順二監訳: "Tooth wearと象牙質知覚過敏"医歯薬出版. 20005.26 (2003)

    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2004-04-14  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI