• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2001 Fiscal Year Final Research Report Summary

Development of the semi conductor imaging spectrometer for hard X-ray and gamma-ray observations

Research Project

Project/Area Number 12554006
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Astronomy
Research InstitutionInstitute of Space and Astronautical Science

Principal Investigator

TAKAHASHI Tadayuki  ISAS, Institute of Space and Astronautical Science, Center for Advanced Satellite Technology Center, Professor, 次世代探査機研究センター, 教授 (50183851)

Co-Investigator(Kenkyū-buntansha) KURODA Yoshikatsu  Mitsubishi Heavy Industries, Ltd., Nagoya Guidance & Propulsion Systems Works, Manager, 名古屋誘導推進システム製作所, 課長
OHNO Ryoichi  ACRORAD CO., LTD. Okinawa Plant, General Manager, 沖縄工場, 取締役
OZAKI Masanobu  ISAS, Institute of Space and Astronautical Science, Research Division for Space Astrophysics, Research Associate, 宇宙圏研究系, 助手 (90300699)
Project Period (FY) 2000 – 2001
KeywordsCdTe / CZT / CdZnTe / Pixel Detector / Radiation Detector / Gamma-ray / Detector
Research Abstract

We have been working on the development of high energy resolution Cadmium Teluride (CdTe) diode detector and its application to the gamma-ray imaging detectors. In this research, we developed a large CdTe diode detector with an area of 2.15 cm by 2.15 cm. It shows very good uniformity throughout the detector area. The energy resolution of 2.7 keV (FWHM) has been achieved. In order for the application in space, we did a vibration test, a radiation test and a balloon experiment. According to the results of these experiments we have proved that CdTe diode can be used in space application. A stack detector with several 10 layers of large CdTe diode was built and tested to prove the performance for the gamma-ray detection. Prototype 1024 pixel detectors with the pixel size of 200 micron by 200 micron and 1 mm by 1 mm are also constructed. From theoretical side, we studied polarization phenomena we often experienced from the CdTe diode in room temperature operation. We found that the charge accumulation due to ionization of deep acceptor is the reason. This explains well about temperature and bias voltage dependence. The characterization of CdZnTe to be used in the Swift mission is another topics. We have developed new method to derive mobility and life time products by fitting energy spectra. This method is adopted by the calibration process of the swift mission.

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] T.Takahashi, et al.: "High-Resolusion Schottky CdTe Diode Detector"IEEE Trans.Nucl.Sci.. Vol.49 No.3. 1297-1303 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] G.Sato, T.Takahashi, et al.: "Characterization of CdTe/CdZnTe Detectors"IEEE Trans.Nucl.Sci.. Vol.49 No.3. 1258-1263 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Y.Okada, T.Takahashi, et al.: "CdTe and CdZnTe detectors for timing measurements"IEEE Trans.Nucl.Sci.. (印刷中). (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] S.Watanabe, T.Takahashi, et al.: "CdTe stacked detectors for Gamma-ray detection"IEEE Trans.Nucl.Sci.. Vol.49 No.3. 1292-1296 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] P.Fischer, T.Takahashi, et al.: "A Counting CdTe Pixel Detector for hard X-ray and Gamma-ray Imaging"IEEE Trans.Nucl.Sci.. (印刷中). (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T. Takahashi, et al.: "High-Resolution Schottky CdTe Diode Detector"IEEE Trans. Nucl. Sci.. Vol.49, No.3. 1297-1303 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] G. Sato, T. Takahashi, et al.: "Characterization of CdTe/CdZnTe detectors"IEEE Trans. Nucl. Sci.. Vol.49, No.3. 1258-1263 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y. Okada, T. Takahashi, et al.: "CdTe and CdZnTe detectors for timing measurements"IEEE Trans. Nucl. Sci.. (in press).

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] S. Watanabe, T. Takahashi, et al.: "CdTe stacked detectors for Gammma-ray detection"IEEE Trans. Nucl. Sci.. Vol.49, No.3. 1292-1296 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] P. Fischer, T. Takahashi, et al.: "A Counting CdTe Pixel Detector for hard X-ray and Gamma-ray Imaging"IEEE Trans. Nucl. Sci.. (in press).

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2003-09-17  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI