• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2002 Fiscal Year Final Research Report Summary

Development of imaging techniques of tissue characterization by means of time domain microwave computed tomography

Research Project

Project/Area Number 12558105
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Biomedical engineering/Biological material science
Research InstitutionNIIGATA UNIVERSITY

Principal Investigator

MIYAKAWA Michio  NIIGATA UNIVERSITY Faculty of Engineering, Professor, 工学部, 教授 (50239357)

Co-Investigator(Kenkyū-buntansha) ISHII Nozomu  Faculty of Engineering, Associate Professor, 工学部, 助教授 (50232236)
Project Period (FY) 2000 – 2002
KeywordsMicrowave computed tomography / Tims domain measurement / Measurement of biological object / Non-invasive measurement / Attenuation- and phase-constant / Distribution / Caring / Time resolution
Research Abstract

1. Conclusions of the study : Feasibility of microwave imaging using measurement techniques in time domain has been investigated. Time domains measurement techniques are used in this study for discriminating the wave components that transmitted on the straight path between two antennas from the scattered- or reflected wave components. This is a similar technique to CP-MCT in which the straight path between two antennas is discriminated by use of the techniques in frequency domain measurement of a chirp radar.
The developed experimental system of Time Domain Microwave Computed Tomography (TD-MCT) that is consisted of a vector network analyzer and microwave scanner and measures S21 in the frequency range from 0.8 GHz to 4.2 GHz. Transmission time between two antennas can be time domain signal is determined by the reflected waves made by placing a metal plate in front of the antenna aperture. Accordingly, the signal which has a specific time interval corresponding to the straight path betw … More een two antennas can be excised from the observed signal to make projection data in frequency domain. This image reconstruction procedure is repeated at every 500 MHz in the frequency range from 1 GHz to 4 GHz. The major differences were observed in the signal to noise ratio and amount of unavoidable artifacts caused by interference among the diffracted- and transmitted-waves. In image reconstruction with 1 GHz bandwidth, the image reconstructed by use of the frequency components from 1 GHz to 2 GHz exhibits the most excellent quality. It is concluded that the CP-MCT that was designed at 1 GHz to 2 GHz has been properly designed. The estimated spatial resolution of TD-MCT shows the same value with that of CP-MCT.
2. Practical significance of time domain microwave computed tomography : Generally speaking, any scanners of microwave computed tomography have to make measurement in bolus saline solution by immersing the antennas and biological object for impedance matching between them. Saline solution shows similar permittivity values with biological tissues in the frequency range of microwave imaging. The advantages of time domain measurement are derived most effectively by increasing the bandwidth of the signal as much as possible. On the other hand, it is hard to increase the frequency of tomographic measurement because transmission loss is increased abruptly when frequency increases. It is also hard to realize the antenna with a very wide bandwidth, for example more than 3 GHz in saline solution. CP-MCT extracts straight path transmission components from transmitted waves in frequency domain and TD-MCT does the same thing in time domain. However, CP-MCT can do it by measuring very low frequency signal which is lower than 1 kHz or less. This is an easy task as compared to the measurement procedure in time domain. It is considered that the advantages of TD-MCT will be found when spectral information can be used effectively. Less

  • Research Products

    (58 results)

All Other

All Publications (58 results)

  • [Publications] M.Miyakawa, K.Orikasa, M.Bertero, P.Boccacci, F.Conte, M.Piana: "Experimental validation of a linear model for data reduction in Chirp-Pulse Microwave CT"IEEE Trans. Medical Imaging. 27. 385-395 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, K.Orikasa, M.Bertero: "Evaluation of the response function and its space dependence in Chirp Pulse Microwave Computed Tomography (CP-MCT)"IEICE, Trans. Information & Systems. E85-D. 52-59 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Bertero, F.Conte, M.Miyakawa, M.Piana: "Computation of the response function in Chirp-Pulse Microwave Computerized Tomography"Inverse Problems. 17. 485-500 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 宮川道夫, 川田洋平, Bertero Mario: "数値計算によるチャープパルスマイクロ波CTの画像生成-ヒト頭部撮像のシミュレーション-"電子情報通信学会論文誌D-II. J84-D-II. 1512-1521 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Bertero, M.Miyakawa, P.Boccacci et al.: "Image restoration in chirp pulse microwave CT (CP-MCT)"IEEE Trans. Biomedical Engineering. 47. 690-699 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Bertero, P.Boccacci, F.Conte, M.Miyakawa, M.Piana: "A linear model for CP-MCT"Proc. of Progress In Electromagnetic Research Symposium 2002. 591 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, Wu Jing, K.Sugawara, M.Bertero: "FDTD-based computation to find an optimal configuration of the printed array antenna used for a fan beam scanner of chirp pulse microwave computed tomography (CP-MCT)"Proc. of Progress In Electromagnetic Research Symposium 2002. 592 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, K.Sugawara, M.Bertero, M.Piana: "Computational Imaging of the Breast-and Head-Models in CP-MCT"Proc. of Progress In Electromagnetic Research Symposium 2002. 593 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, E.Harada, N.Ishii, M.Bertero: "Development of a printed dipole array antenna for fan beam-type chirp-pulse microwave computed tomography (CP-MCT)"Proc. of Progress In Electromagnetic Research Symposium 2002. 871 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, M.Eiyama, N.Ishii: "An attempt of time-domain microwave computed tomography for biomedical use"Proc. IEEE EMB International Symposium, in Istanbul, Turkey, Oct. 24-28, 2001. (CD-ROM). (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, K.Kitamura, M.Eiyama, et al.: "Imaging of biological targets by the prototype model and a high resolution model of CP-MCT"Proc. of Progress In Electromagnetic Research Symposium 2000. 1. 152 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Miyakawa, Y.Kawada, N.Ishii, et al.: "Computational and experimental determination of the PSF in CP-MCT"Proc. of Progress In Electromagnetic Research Symposium 2000. 1. 231 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 宮川道夫(共著): "マイクロ波CT技術-あらたな生体情報の獲得を目指して-""バイオイメージング"菊地眞編 医歯薬出版,東京. 94 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Bertero, F.Conte, M.Piana, M.Miyakawa: "Approximate mathematical models for CP-MCT and comparison with FD-TD computations"Proc. of Progress In Electromagnetic Research Symposium 2000. 1. 15 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 宮川道夫: "医用生体工学研究の最前線(その2)"電磁波による生体情報の可視化""電気学会誌. 120. 281-284 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 宮川道夫: "マイクロ波イメージング-CT計測の現状と展望-"東北大学電気通信研究所共同プロジェクト研究「ミリ波帯イメージング技術の開発と各種波動を用いたイメージング技術の研究」研究会講演資料集. 83-86 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 呉 晶, 菅原邦義, 宮川道夫: "ファンビーム型スキャナにおけるアンテナ素子の最適配置"電子情報通信学会技術研究報告. MBE2002. 33-36 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 原田枝実子, 呉晶, 宮川道夫: "ファンビーム型マイクロ波CT用受信アンテナの実験による最適配置"電子情報通信学会技術研究報告. MBE2002. 29-32 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 竹内俊吾, 原田枝実子, 菅原邦義, 宮川道夫, 石井 望: "実効的高速撮像を目的としたファンビームマイクロ波CTの改良"電子情報通信学会技術研究報告. MBE2001. 17-22 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 北村恵一, 宮川道夫, 石井 望: "高分解能型CP-MCTの基礎的検討"電子情報通信学会技術研究報告. MBE2000. 31-38 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 伊藤 洋, 宮川道夫, 石井 望: "ファンビーム型スキャナのチャープレーダ方式マイクロ波CT"電子情報通信学会技術研究報告. MBE99. 7-12 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 折笠健太郎, 宮川道夫, 石井 望: "FDTD法によるCP-MCTのPSF算出と画像改善手法"電子情報通信学会技術研究報告. MBE99. 13-18 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 永山正登, 宮川道夫: "タイムドメインマイクロ波CTの可能性"電子情報通信学会総合大会論文誌、情報・システム分冊. 82 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 原田枝実子, 呉晶, 宮川道夫: "プリント化ダイポールアンテナを用いたファンビーム型CP-MCT"第41回日本エムイー学会大会論文誌. 40. 225 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 菅原邦義, 宮川道夫, 石井 望: "CP-MCTによる頭部および胸部の撮像-三次元モデルを用いた数値計算-"第41回日本エムイー学会大会論文誌. 40. 226 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 宮川, 小塚, 遠藤他12名: "電気学会編「先端放射線医療技術と計測」"コロナ社,東京. 222 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M. Miyakawa, K. Orikasa, M. Bertero, and et al.: "Experimental validation of a linear model for data reduction in Chirp-Pulse Microwave CT"IEEE Trans. Medical Imaging. Vol. 27, No. 4. 385-395 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, K. Orikasa, and M. Bertero: "Evaluation of the response function and its space dependence in Chirp Pulse Microwave Computed Tomography (CP-MCT)"IEICE Japan, Trans. Inf. & Syst.. Vol. E85-D, No. 1. 52-59 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Bertero, P. Boccacci, F. Conte, M. Miyakawa, and M. Piana: "A linear model for CP-MCT"Proc. PIERS 2002 in Cambridge. July 1-5. 591 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, W. Jing, K. Sugawara, and M. Bertero: "FDTD-based computation to find an optimal configuration of the printed array antenna used for a fan beam scanner of chirp pulse microwave computed tomography (CP-MCT)"Proc. PIERS 2002 in Cambridge. July 1-5. 592 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, K. Sugawara, M. Bertero, and M. Piana: "Computational Imaging of the Breast- and Head-Models in CP-MCT"Proc. PIERS 2002 in Cambridge. July 1-5. 593 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, E. Harada, N. Ishii, and M. Bertero: "Development of a printed dipole array antenna for fan beam-type chirp-pulse microwave computed tomography (CP-MCT)"Proc. PIERS 2002 in Cambridge. July 1-5. 871 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa: "Microwave imaging - Present situation and the future"Proc. Of Academic meeting on millimeter wave imaging and imaging studies using various kinds of waves. 83-86 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] W. Jing, K. Sugawara, and M. Miyakawa: "Optimal arrangement of receiving antenna elements in fan beam-type microwave scanner"Technical Rep. IEICE Japan. MBE2002-81. 33-36 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] E. Harada, W. Jing, M. Miyakawa: "Experimental determination of the optimal arrangement of a receiving antenna consisted of dipole antennas for microwave imaging"Technical Rep. lEICE Japan. MBE2002-80. 29-32 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Eiyama, and M. Miyakawa: "Feasibility of microwave computed tomography"Proc. Annual Meetings of IEICE Japan, Inform. & Systems. D-7-13. 82 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] E. Harada, W. Jing, and M. Miyakawa: "Fan beam-type CP-MCT using a printed dipole array antenna"Proc. 41-th Annual Meeting of Jpn. Soc. Med. & Biol. Eng.. 22I-03. 225 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Sugawara, M. Miyakawa, and N. Isnii: "Imaging of a human head and breast with CP-MCT - Numerical computation based on the three dimensional models"Proc. 41-th Annual Meeting of Jpn. Soc. Med. & Biol. Eng.. 22I-04. 226 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Bertero, F. Conte, M. Miyakawa, and M. Piana: "Computation of the response function in Chirp-Pulse Microwave Computerized Tomography"Inverse Problems. Vol. 17. 485-500 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, Y. Kawada, and M. Bertero: "Image generation of Chirp-Pulse Microwave Computerized Tomography (CP-MCT) by numerical computation - Computation of the human head model"IEICE Japan, Trans. Inf. & Syst. D-II. Vol. I84-D-II, No. 7. 1512-1521 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, M. Eiyama, and K. Ishii: "An attempt of time-domain microwave computed tomography for biomedical use"Proc. IEEE EMB International Symposium, in Istanbul, Turkey. Oct.. 24-28 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] S. Takeuchi, E. Harada, K. Sugawara, M. Miyakawa et al.: "Improvement of the fan beam microwave computed tomography aiming at effective high-speed imaging"Technical Rep. IEICE Japan. MBE2001-73. 17-22 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Eiyama, M. Miyakawa, and N. Ishii: "Time domain microwave computed tomography - Configuration of a measurement system"Proc. 40-th Annual Meeting of Jpn. Soc. Med. & Biol. Eng.. 3pC1-1. 484 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Sugawara, M. Miyakawa, and N. Ishii: "Diagnostic information for early detection of breast tumors by CP-MCT - Feasibility study by numerical analysis of the model"Proc. 40-th Annual Meeting of Jpn. Soc. Med. & Biol. Eng.. 3pC1-2. 485 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Bertero, M. Miyakawa, P. Boccacci, et al.: "Image restoration in chirp pulse microwave CT (CP-MCT)"IEEE Trans. Biomedical Engineering. Vol. 47, No. 5. 690-699 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, K. Kitamura, M. Eiyama, N. Isnii, M. Bertero, P. Boccacci: "Imaging of biological targets by the prototype model and a high resolution model of CP-MCT"Proc. PIERS 2000 in Cambridge MA. July 5-14, Vol. 1. 152 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, Y. Kawada, N. Isnii, M. Bertero and P. Boccacci: "Computational and experimental determination of the PSF in CP-MCT"Proc. PIERS 2000 in Cambridge MA. July 5-14, Vol. 1. 231 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Bertero, F. Conte, M. Piana, and M. Miyakawa: "Approximate mathematical models for CP-MCT and comparison with FD-TD computations"Proc. PIERS 2000 in Cambridge MA. July 5-14., Vol. 1. 15 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa: "Microwave Computed Tomography Aiming At New biological Information, in "Bioimaging" edited by M. Kikuchi""Bio Imaging", Ishi-yaku Publishing Co.. 77-80 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa: "Frontier of Bio-Medical Engineering Researches Part II - Visualization of biological information by use of electromagnetic waves"J. of IEE Japan. Vol.120, No. 5. 281-284 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Kitamura, M. Miyakawa and N. Ishii: "Abasic study on the high resolution-type CP-MCT"Technical Rep. IEICE Japan. MBE2000-89. 31-38 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] H. Itoh, M. Miyakawa and N. Ishii: "A chirp pulse microwave computed tomography"Technical Rep. IEICE Japan. MBE99-146. 7-12 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Orikasa, M. Miyakawa and N. Ishii: "PSF-based image restoration of CP-MCT by use of FDTD method"Technical Rep. IEICE Japan. MBE99-147. 13-18 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Eiyama, M. Miyakawa and N. Isnii: "A basic study of time-domain microwave computed tomography"Proc. 14-th Automnl Meeting of Jpn. Soc. Med. & Biol. Eng.. 1RB2-1. 53 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] K. Kitamura, M. Miyakawa and N. Ishii: "An attempt of acid and sugar imaging contained in fruits"Proc. 14-th Autumnl Meeting of Jpn. Soc. Med. & Biol. Eng.. 1RB2-2. 54 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Y. Kawada, M. Miyakawa and N. Ishii: "Imaging of temperature variation by the microwave computed tomography - Measurement and computation method"Proc. 39-th Annual Meeting of Jpn. Soc. Med. & Biol. Eng.. 3F3-3. 470 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Eiyama, M. Miyakawa and N. Ishii: "Imaging of temperature variation by the microwave computed tomography - Measurement and attenuation and phase shift"Proc. 39-th Annual Meeting of Jpn. Soc, Med. & Biol. Eng.. 3F3-4. 471 (2000)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M. Miyakawa, Y. Kotsuka, S. Endoh et al.: "Advanced Radiological Treatment Techniques and Measurement"Corona Publishing Co. Ltd, Tokyo. 175-184 (2001)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2004-04-14  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI