Study of bubbles formation in organic tissue subjected to pressure variation environments and bubble embolism

Research Project

Project/Area Number 12650174
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Fluid engineering
Research InstitutionKumamoto University

Principal Investigator

TSUJINO Tomoji  Kumamoto University, Faculty of Education, Professor, 教育学部, 教授 (80006197)

Co-Investigator(Kenkyū-buntansha) IKOHAGI Toshiaki  Tohoku University, Institute of Fluid Science, Professor, 流体科学研究所, 教授 (90091652)
Project Period (FY) 2000 – 2003
Keywordsbubble embolism / decompression disease / bubble / artificial valve / cavitation / submarine sickness / pulsatile flow / soft organic tissue
Research Abstract

Bubbles often generate in organic tissue subjected to pressure variation of environments, and consequently the bubbles are responsible for bubble embolism. In this work, the experimental studies are conducted from viewpoint of fluid dynamics in order to clarify decompression disease such as submarine sickness and complication after substitution of an artificial heart valve.
(1)During the flow in the pipe with small diameter of 1.15mm, the bubbles of diameter 0.06mm〜0.84mm are generated in oversaturated liquid-gas solutions (oxygen, carbon dioxide, helium). The incorporation phenomena of bubbles and the formation of chain bubbles are also observed. The number of bubbles increase with increasing of gas additional pressure and flow velocity in pipe. In the liquids solved carbon dioxide, the size and the number of occurring bubbles are larger than the case in oxygen and helium. The bubbly flow in the small pipe may be cause of obstruction an of arteriola and venula.
(2)In soft organic tissue such as musclar model and fat moder under the conditions of high gas pressure, the bubbles also occur. Carbon dioxide bubbles are easy to make in fat model, and the number of bubble density of helium is large as compare with the cases of oxygen, carbon dioxide.
(3)Cavitation phenomena are detected around an artificial valve in pulsatile flow with high velocity. In the conditions of flow rate Q=5L/min and mean flow velocity v=0.57m/s, cavitation bubbles are observed in downstream of aortic valve. The bubbles of the size of 0.2mm〜0.5 mm are detected around aortic valve, and the velocities of movement of the bubbles are 0.46m/s〜1.2m/s. On the upstream side of aortic valve, cavitation phenomena are produced explosively at closing of the valve. The small bubbles produced around artificial valve are responsible for embolism in cardiovascular system and HITS.

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] 辻野智二: "人工弁まわりのキャビテーション発生"キャビテーションシンポジウムプロシーディングス. 12. 89-92 (2004)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 辻野智二: "狭い隙間におけるキャビテーション損傷に及ぼすポリマー効果に関する研究"熊本大学教育学部紀要、自然科学. 52. 1-6 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 辻野智二: "ガス過飽和液体中の気液二相流動に関する研究"熊本大学教育学部紀要、自然科学. 51. 19-30 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 辻野智二: "左補助用マイクロ血液ポンプの試作に関する研究"ターボ機械. 30. 479-485 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 辻野智二: "二葉式機械弁におけるキャビテーション気泡の生成とその動態"人工臓器. 29. 379-383 (2000)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Tsujino, M.Miura, T.Ikohagi, K.Hirakawa: "Cavitation Occurrence around Artificial Valves"Proceedings of Cavitation Symposium. Vol.12. 89-92 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Tsujino, K.Inoue, T.Ohashi: "Study of Polymer Effect on Cavitation Damage in Narrow Clearance"Memoirs of the Faculty of Education, Kumamoto University. Vo.52. 1-6 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Tsujino, K.Inoue: "Study of Two-Phase Flow in Oversaturated Liquid-Gas Solutions"Memoirs of the Faculty of Education, Kumamoto University. Vo.51. 19-30 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Tsujino, M.Miura, K.Uranishi, M.Tsukamoto, K.Hirai: "An Experimental Study of Micro Blood Pump for Left Ventricular Assist"Turbomachinery. Vol.30-8. 479-485 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Miura, T.Tsujino: "Experimental Study of Cavitation Occurrence and Bubble Behaviors Around, Artificial Heart Valve"The Japanese Journal of Artificial Organs. Vol.29. 379-383 (2000)

    • Description
      「研究成果報告書概要(欧文)」より