• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2002 Fiscal Year Final Research Report Summary

Transbronchial lung volume reduction by diode laser heat probe (Indigo 830) for lung emphysema

Research Project

Project/Area Number 12671299
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Thoracic surgery
Research InstitutionChiba University

Principal Investigator

SEKINE Yasuo  Chiba University, Graduate School of Medicine, Assistant, 大学院・医学研究院, 助手 (70312957)

Co-Investigator(Kenkyū-buntansha) FUJISAWA Takehiko  Chiba University, Graduate School of Medicine, Professor, 大学院・医学研究院, 教授 (80110328)
SAITOH Yukio  Chiba University, Graduate School of Medicine, Lecturer, 大学院・医学研究院, 講師 (60261905)
Project Period (FY) 2000 – 2002
Keywordsemphysema / lung volume reduction / transbronchial / heat probe
Research Abstract

(1) Irradiation effect on pulmonary parenchyma by a heat probe (indigo 830)
Under general anesthesia and unilateral ventilation, transbronchial irradiation by a heat probe was performed. Under the condition of 80 degree centigrade for 5 minutes, coagulation area was 25 by 10 mm, which was equivalent to that under 90 and 100 degrees for 5 minutes. However, Under 90 and 100 degrees, a part of the lung was changed necrosis, static compliance was decreased from 21.2 to 7.1 ml/cmH2O (33.5% reduction).
(2) The best condition of pulmonary coagulation for lung volume reduction
Under the three conditions as follows, irradiation was performed and the best condition for volume reduction was evaluated. 1) Under spontaneous ventilation with lung expansion, 2) no ventilation with lung expansion and 3) no ventilation with lung collapse by thoracotomy. No heat elevation was observed under the condition #1. A small coagulation was observed under the condition #2. Well coagulation was observed under the condition #3.
(3) Lung emphysema model
One month after inhalation of 40 mg/kg of papain to a mini pig, lung mechanics (intra-bronchial air pressure, flow volume, airway resistance and compliance) was measured. Static compliance elevated from 23 +/- 3.5 ml/H2O before inhalation to 33.3 +/- 4.6 ml/H2O after inhalation(n=3). Pathologically, lung emphysema was confirmed.
(4) The effect of laser irradiation on emphysema lung
The static compliance was reduced from 21.2 +/- 3.7 ml/H2O to 7.1 +/- 2.5 ml/H2O (33% reduction) after papain inhalation. After irradiation, that was re-elevation to 13.8 ml/H2O.

  • Research Products

    (4 results)

All Other

All Publications (4 results)

  • [Publications] Sekine Y, Iwata T, Chiyo M, et al.: "Minimal Alteration of Pulmonary Function after Lobectomy in Lung Cancer Patients with COPD"Annals of Thoracic Surgery. (in press).

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Chiyo M, Sekine Y, Iwata T, et al.: "Impact of Interstitial Lung Disease on Surgical Morbidity and Mortality for Lung Cancer : Analyses of Short and Long-Term Outcomes"Journal of Thoracic and Cardiovascular Surgery. (in press).

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Sekine Y, Iwata T, Chiyo M, et al.: "Minimal Alteration of Pulmonary Function after Lobectomy in Lung Cancer Patients with COPD"Annals of Thoracic Surgery. in press. (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Chiyo M, Sekine Y, Iwata T, et al.: "Impact of Interstitial Lung Disease on Surgical Morbidity and Mortality for Lung Cancer : Analyses of Short and Long-Term Outcomes"Journal of Thoracic and Cardiovascular Surgery. in press. (2003)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2004-04-14  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI