• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2002 Fiscal Year Final Research Report Summary

Development of the functional bad bearing device for hip joint

Research Project

Project/Area Number 12794021
Research Category

Grant-in-Aid for University and Society Collaboration

Allocation TypeSingle-year Grants
Research Field Biomedical engineering/Biological material science
Research InstitutionNIIGATA UNIVERSITY

Principal Investigator

HARA Toshiaki  Faculty of Engineering Professor, 工学部, 教授 (50134953)

Co-Investigator(Kenkyū-buntansha) NITTA Isami  Faculty of Engineering Associate Professor, 工学部, 助教授 (30159082)
OOMORI Go  Graduate School of Medical and Dental Sciences Associate Professor, 大学院・医歯学総合研究科, 助教授 (70283009)
ENDOU Naoto  Graduate School of Medical and Dental Sciences Professor, 大学院・医歯学総合研究科, 教授 (10251810)
SATOU Kazuo  Central Niigata Prefecture Industrial Promotion Center Development Section Chief, 技術開発課, 技術開発課長(研究職)
HOSHI Teruo  Mizuho Medical Engineering Co. Development Section Director, 開発部長(研究職)
Project Period (FY) 2000 – 2002
Keywordsdevice / Perthes disease / load bearing function / Orthopaedics / hip joint / biomechanics / stress analysis / optimum design
Research Abstract

In tins research project, new developments in orthopaedic implants and new manufacturing technologies have been closely tied for the past three years Manufacturability has been required to transform successful biomechanical and collaborated research into a successful medical product especially for Perthes disease. The device obtained its strength from Ti-6A1-4V metal alloy, its load bearing function with flexibility through special designed linkage, and its fixation through a pelvic surface though this collaboration has experienced difficulties in achieving functional effectiveness and fulfilling product design and anatomic requirements. As a results, some devices for clinical trial are currently made by the applications of redesign to earlier developed devices for this project.
Experimental analysis was carried out on 7 hip models with the special designed devive, including normal joints and joints affected with Perthes diseases. Three-dimensional hip motion data on the ability of dail … More y life including evacuation and sedentary occupation for female and male was analyzed by standard gait analysis techniques, using video analysis and electrogoniometers. The results from the motion data proved the efficacy of the device and the ability of evacuation and sedentary occupation although there is the motion containment of the hip.
In addition, three-dimensional femoral head contact with the acetabulum was studied to investigate the load bearing function of the device using electric conductive rubber pressure sensor systems. It was found that there was significant difference in the contact stress between joint models with/without the device.
Finally we studied the theoretical stress distribution in the pelvis-device-proximal femur united model by means of a three-dimensional finite element method to determine the qualitative parameters on stress distribution in the model during gait and daily life, the deformability, and the fixational rigidity.
We conclude that the university and society collaboration has been successfully carried out to develop the new orthopaedic device which has the endurability and clinical applicability and that some new technologies have demonstrated functionality, cost effectiveness, and regulatory approvability. Less

  • Research Products

    (8 results)

All Other

All Publications (8 results)

  • [Publications] 山子 剛: "股関節用免荷デバイスのメカニズム"日本機械学会2003年度年次大会講演論文集('03.8.5〜8 徳島市). No.03-1(発表予定). (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 永井重之: "股関節用免荷デバイスの可動性評価"日本機械学会第13回バイオエンジニアリング学術講演会・秋季セミナー講演論文集. No.20-26. 49-50 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 飯吉弘喜: "股関節用免荷デバイスの免荷能力評価"日本機械学会第13回バイオエンジニアリング学術講演会・秋季セミナー講演論文集. No.02-26. 47-48 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 内橋 悟: "pQCTを利用したサル大腿骨頸部の強度推定"日本機械学会第15回バイオエンジニアリング講演会論文集. No.02-35. 81-82 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Go Yamako, Naoto Endou and Toshiaki Hara: "Mechanism of load bearing device for hip joint"Proceedings of the 2003 JSME Annual Meeting. No.03-1(to appear). (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Shigeyuki Nagai, Hiroki liyoshi, Itaru Kourakata, Naoto Endo and Toshiaki Hrara: "Mobility Evaluation of the Nonweight-bearing Device for Hip Joint"Proceeding of the 13rd JSME Autumn Bioengineering Conference and Seminar. No.02-26. 49-50 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hiroki liyoshi, Shigeyuki Nagai, Itaru Kourakata, Naoto Endo and Toshiaki Hrara: "Functional Evaluation of the Nonweight-bearing Device for Hip Joint"Proceeding oTthe 13rd JSME Autumn Bioengineering Conference and Seminar. No.02-26. 47-48 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Satoru Uchihashi, Masayuki Ito, Naoto Endo and Toshiaki Hara: "Mechanical Property Prediction of monkey femoral neck using pQCT"Proceeding of the 15th Bioengineering Conference 2002 Annual Meeting of BE/JSME. No.02-35. 81-82 (2002)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2004-04-14  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI