Basic study on electrical insulation test method and electrical insulation design of HTS power devices

Research Project

Project/Area Number 13450114
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 電力工学・電気機器工学
Research InstitutionKyushu University

Principal Investigator

HARA Msanori  Kyushu University, Graduate School of Information Science and Electrical Engineering, Professor, 大学院・システム情報科学研究院, 教授 (30039127)

Co-Investigator(Kenkyū-buntansha) IMASAKA Kiminobu  Kyushu University, Graduate School of Information Science and Electrical Engineering, Assistant, 大学院・システム情報科学研究院, 助手 (40264072)
SUEHIRO Junya  Kyushu University, Graduate School of Information Science and Electrical Engineering, Assistant professor, 大学院・システム情報科学研究院, 助教授 (70206382)
Project Period (FY) 2001 – 2003
KeywordsHigh temperature Superconducting Power Devices / Electrical Insulation Technology / High Voltage Test Method / Partial Discharge Onset / Equivalent High Voltage Test Method / SC Coil for HTS Tr. / Medium Factor / Quench
Research Abstract

The electrical insulation system of the high temperature superconducting(HTS) power devices is generally placed in the pool of cryogenic coolant. Moreover, the quench phenomena are inevitable in it and its dielectric strength is significantly reduced if the coolant vaporizes due to the Joule heat at the quenched part of the superconductor. Then, these two factors must be taken into the insulation design, and also considered in high voltage tests to secure the reliability of the designed electrical insulation. In the present research, the equivalent high voltage testing method at room temperature for promising HTS power devices at the stages of development, manufacturing and shipment is studied. The determination method of the equivalent insulation test voltage at room temperature is proposed and the application of the method to the HTS power devices is attempted. Especially, the basic parameter of "Medium Factor" for the estimation of the equivalent insulation test voltage is proposed and its usefulness is confirmed by experiments using modeled HTS coil elements and real coils.

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] T.Kurihara: "PD Characteristics in an Air-filled Void at Room Temperature under Superimposed Sinusoidal Voltages"IEEE Trans.on Dielectrics and Electrical Insulation. 8. 269-275 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 原 雅則: "高温超伝導コイルにおける交流電圧印加時の熱気泡挙動と電気絶縁環境"低温工学. 36. 406-418 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 原 雅則: "三重点近傍におけるガス中の部分放電開始特性の推定"電気学会論文誌. 122-A. 650-657 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 栗原 隆史: "三重点近傍の大気圧空気中における部分放電特性の測定"放電研究. 41. 15-21 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Kurihara: "Partial Discharge Characteristics in an Artificial Air-filled Void under Super imposed Sinusoidal Voltages at LN_2 Temperature"IEEJ Trans.on PE. 123. 1280-1287 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] T.Kurihara, S.Kozuru, K.Imasaka, J.Suehiro, M.Hara: "PD Characteristics in an Air-filled Void at Room Temperature under Superimposed Sinusoidal Voltages"IEEE Trans.on Dielectrics and Electrical Insulation. Vol.8, No.2. 269-275 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Hara, J.Suehiro, M.Kushinaga, Y.Matsumoto, K.Funaki, M.Iwakuma, T.Bohno, K.Tsutsumi: "Behavior of Thermally Induced Bubbles and State of Electrical Insulation Medium in HTC Superconducting Coil Stressed by AC Voltage"Cryogenic Engineering. Vol.36, No.7. 406-418 (2001)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] M.Hara, T.Kurihara, S.Kozuru, J.Suehiro, N.Hayashi: "Esitimation of Partial Discharge Onset Characteristices in Gases around a Triple Junction"Trans.IEE of Japan. Vol.122-A, No.7. 650-657 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Kurihara, T.Nishioka, J.Suehiro, N.Hayashi, M.Hara: "Measurements of Partial Discharge Characteristics near a Triple Junction in Atmospheric Air"Journal of The Institute of Engineers on Electrical Discharges in Japan. Vol.41, No.1. 15-21 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] T.Kurihara, T.Nishioka, J.Suehiro, M.Hara: "Partial Discharge Characteristics in an Artificial Air-filled Void under Superimposed Sinusoidal Voltages at LN_2 Temperature"IEEJ Trans.on PE. Vol.123, No.11. 1280-1287 (2003)

    • Description
      「研究成果報告書概要(欧文)」より