Development of non-invasive standardized equipment for diagnosis of chronic peripheral obstructive vascular diseases

Research Project

Project/Area Number 13557033
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section展開研究
Research Field Public health/Health science
Research InstitutionYamaguchi University

Principal Investigator

HARADA Noriaki  Yamaguchi University, School of Medicine, Professor, 医学部, 教授 (70116747)

Co-Investigator(Kenkyū-buntansha) IWAMOTO Mieko  Yamaguchi University, School of Medicine, Professor, 医学部, 教授 (80034932)
INOUE Masaiwa  Yamaguchi University, School of Medicine, Associate Professor, 医学部, 助教授 (20335722)
SHAWKATUZZAMAN L  Yamaguchi University, School of Medicine, Research Associate, 医学部, 助手 (30379945)
YOKOYAMA Kenjirou  Yamaguchi University, School of Medicine, Research Associate, 医学部, 助手 (70346550)
NAKANO Kimihiko  Yamaguchi University, Faculty of Engineering, Professor, 工学部, 助教授 (90325241)
Project Period (FY) 2001 – 2004
Keywordsperipheral obstructive vascular diseases / Raynaud's phenomenon / non-invasion / diagnosis / finger skin temperature / finger systolic blood pressure / cold provocation / standardization
Research Abstract

For developing non-invasive standardized equipment for diagnosis of chronic obstructive vascular diseases, two cold provocation tests, finger skin temperature measurement and finger systolic blood pressure measurement were investigated. For finger skin temperature measurement, effects of water temperature and duration of cold immersion, and gloves on the test results were examined. And, for finger systolic blood pressure, effects of room temperature and subject posture on the test results were examined. With systemic review of relevant literatures and discussions with representative researchers, including foreign researchers invited to our university for public lectures (2002) and workshop (2004), norm of equipment together with the concrete tests methods and conditions were proposed as drafts for international standards (ISO/FDIS 14835-1 and 14835-2) in 2005.

  • Research Products

    (11 results)

All 2005 2004

All Journal Article (10 results) Book (1 results)

  • [Journal Article] Effects of waterproof covering on hand immersion tests using water of 10℃,12℃ and 15℃ for diagnosing hand-arm vibration syndrome2005

    • Author(s)
      Kumiko Suizu
    • Journal Title

      Int Arch Occup Environ Health (in press)

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Effect of room temperature on percentage finger systolic blood pressure response to finger cooling2005

    • Author(s)
      MS Laskar
    • Journal Title

      Eur J Applied Physiology (in press)

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Effects of waterproof covering on hand immersion tests using water of 10℃, 12℃ and 15℃ for diagnosing hand-arm vibration syndrome2005

    • Author(s)
      Suizu K
    • Journal Title

      Int Arch Occup Environ Health 78

      Pages: 311-318

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Effect of room temperature on percentage finger systolic blood pressure response to finger cooling2005

    • Author(s)
      Laskar MS
    • Journal Title

      Eur J Applied Physiology (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Occupational exposure limit for hand-arm vibration of the Japan Society for Occupational Health2004

    • Author(s)
      Harada N
    • Journal Title

      Proc 9^<th> Int Con on Hand-arm Vibration

      Pages: 90-96

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Influence of room temperature on finger systolic blood pressure response to finger cooling in healthy subjects2004

    • Author(s)
      Laskar MS
    • Journal Title

      Proc 10th Int Con on Hand-Arm Vibration

      Pages: 163-164

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Effect of handle temperature on temporary threshold shift of fingertip vibration sensation and finger skin temperature2004

    • Author(s)
      Yokoyama K
    • Journal Title

      Proc 10th Int Con on Hand-Arm Vibration

      Pages: 71-72

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Influence of waterproof covering on finger skin temperature and hand pain during immersion test for diagnosing hand-arm vibration syndrome2004

    • Author(s)
      Suizu K
    • Journal Title

      Ind Health 42

      Pages: 79-82

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Influence of room temperature on finger systolic blood pressure response to finger cooling in healthy subjects2004

    • Author(s)
      Laskar MS
    • Journal Title

      Proc 10^<th> Int Con on Hand-Arm Vibration

      Pages: 163-164

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Effect of handle temperature on temporary threshold fingertip vibration sensation and finger skin temperature2004

    • Author(s)
      Yokoyama K
    • Journal Title

      Proc 1O^<th> Int Con on Hand-Arm shift of Vibration

      Pages: 71-72

    • Description
      「研究成果報告書概要(欧文)」より
  • [Book] 手腕振動障害-その免疫・病態から予防まで-2004

    • Author(s)
      山田信也
    • Total Pages
      262
    • Publisher
      労働科学研究所出版部
    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2006-07-11   Modified: 2021-04-07  