2002 Fiscal Year Final Research Report Summary
Research of Nuclear Excitation by Electron Transition on ^<189>Os
Project/Area Number |
13640311
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
素粒子・核・宇宙線
|
Research Institution | High Energy Accelerator Research Organization |
Principal Investigator |
KISHIMOTO Shunji Institute of Materials Structure Science, High Energy Accelerator Research Organization, Assistant Professor, 物質構造科学研究所, 助教授 (00195231)
|
Project Period (FY) |
2001 – 2002
|
Keywords | Nuclear Excitation / NEET / Os-189 / Synchrotron X-rays / AvalanchePhotodiodes / Internal-conversion Electrons / Time spectroscopy |
Research Abstract |
In FY2001, we developed an internal-conversion electron detector with nety silicon avalanche photodiodes (Si-APDs). The detector had two monolithic Si-APD arrays ofthitee pixels (3 mm in diameter), installed in a vacuum chamber. We tested the detector at beamline BL-14A of the Photon Factory using 8.4-keV x-rays. The results had a problem that the energy resolution ofthe Si-APD array was worse than that of a normal device due to a large difference of gains cn position in the detection area. Though we could not use the new Si-APDs, we tried to observe; the nuclear excitation by electrontransition (NEET) on ^<193>Ir, as we scheduled in our plan, with the detector that had one Si-APD in the vacuum chamber. The experiment was done at BL09XU of the SPring-8. We successfully observed NEET, of which probability was less than one tenth otfthat on ^<197>Au. Ourresult of the NEET probability was (2.8±0.2)×10^<-9>, while a recent calculation presented a value of 2.0×10^<-9>. The difference between the results will be discussed. In FY2002, the Si-APD array was improved and tested again at BL-14A. The energy resolution became better and the arrays were installed in the detector. However, we did not have a chance for executing an experiment for NEET on ^<189>Os due to a delay of improving the Si-APD and due to atrouble in the accelerator within a period of our experiment at the SPring-8. After FY2002, in April 2003, we have tried to observe NEET on ^<I89>Os at BL09XU of the SPring-8. In the experiment, we used another Si-APDs because a signal-to-noise ratio of the Si-APD array was smaller than that we expected. With the detector, NEET on ^<189>Os was still not observed in the K-shell ionization. The improvement in the detector for a better signal-to-noise ratio will be continued.
|
Research Products