• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2002 Fiscal Year Final Research Report Summary

Development of simple "capillary electrophoresis - chemiluminescence detection" system and its application to a gene diagnosis

Research Project

Project/Area Number 13650873
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field 工業分析化学
Research InstitutionDoshisha University

Principal Investigator

TSUKAGOSHI Kazuhiko  Doshisha University, Department of Chemical Engineering and Materials Science ; Professor, 工学部, 教授 (60227361)

Project Period (FY) 2001 – 2002
KeywordsCapillary electrophoresis / Chemiluminescence / DNA / Sensitive analysis / Separation ・ detection
Research Abstract

A simple and convenient chemiluminescence detection cell was designed for capillary electrophoresis. The detection cell easily combined with capillary electrophoresis equipment. Luminol chemiluminescence was adapted for use with the detection cell. Detailed analysis and testing of the system revealed that luminol could be determined over a range of 2.5 x 10^<-10> to 6.5 x 10^<-7> M (correlation coefficient, 0.999), with a detection limit (S/N=3) of 2.5 x 10^<-10> M (7 amol). Furthermore, each component in a mixture of glycine, glycylglycine, and glycylglycylglycine, which were labeled with isoluminol isothiocyanate, was baseline separated and sensitively detected. Moreover, the stacking procedure was applied to post column detection in capillary electrophoresis. When using acetonitrile stacking under certain conditions in the present system, chemiluminescence intensities of luminol and labeled compounds were about an order of magnitude higher than those obtained without stacking. The d … More etection limit for luminol was 1.5 x 10^<-11> M (S/N=3), representing the highest sensitivity of luminol yet reported. Also, the effect of p-iodophenol as an enhancer of luminol chemiluminescence was examined under weak alkaline conditions. The chemiluminescence intensity of luminol was about two orders of magnitude higher than that in the unenhanced reaction.
Next, we developed capillary electrophoresis with chemiluminescence detector using a polymer solution as separation medium for analysis of biopolymers, such as DNA and protein. Peroxyoxalate chemiluminescence reagent of bis (2,4,6-trichlorophenyl)oxalate was used together with fluorescein-labeling reagent. Fluorescein-labeled DNA was prepared through polymerase chain reaction using fluorescein-labeled deoxyadenosine triphosphate. A mixture of the labeled DNA fragments (500, 600, 700, 800, 900, and 993 bp) was successfully separated and detected by the present system. A mixture of proteins (lysozyme, cytochrome C, and ribonuclease A) which were labeled with fluoresein isothiocyanate was also separated and detected. Less

  • Research Products

    (10 results)

All Other

All Publications (10 results)

  • [Publications] Kazuhiko Tsukagoshi: "Consideration on Peak Shape in Batch-type Chemiluminescence Detection Cell for Capillary Electrophoresis"Journal of Chromatography A. 930. 165-169 (2001)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi: "Separation and Determination of Emetine Dithiocarbamate Metal Complexes by Capillary Electrophoresis with Chemiluminescence Detection of the Tris(2,2'-bipyridine) Ruthenium(II) Complex"Journal of Chromatography A. 953. 283-289 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi: "Miniaturization of Batch-and Flow-type Chemiluminescence Detector in Capillary Electrophoresis"Journal of Chromatography A. 971. 255-260 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi: "Batch-Type Chemiluminescence Detection Cell for Sensitization and Simplification of Capillary Electrophoresis"Analytical Chemistry. 74. 4109-4116 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi: "Application of Capillary Electrophoresis with Sensitive Detection to Analysis for Saccharide Molecules"Analytical Science. 18. 709-710 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi: "Analysis of a Biopolymer by Capillary Electrophoresis with a Chemiluminescence Detector Using a Polymer Solution as the Separation Medium"Analytical Science. 18. 1195-1198 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiko Tsukagoshi, Takeshi Nakamura, and Riichiro Nakajima: "Batch-type Chemiluminescence Detection Cell for Sensitization and Simplification of Capillary Electrophoresis"Analytical Chemistry. 74. 4109-4116 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kazuhiko Tsukagoshi, Yuki Obata, and Riichiro Nakajima: "Miniaturization of Batch- and Flow-type Chemiluminescence Detector in Capillary Electrophoresis"Journal of Chromatography A. 971. 255-260 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kazuhiko Tsukagoshi, Yuki Obata, Takaaki Kanamori, and Riichiro Nakajima: "Application of Capillary Electrophoresis with Sensitive Detection to Analysis for Saccharide Molecules"Analytical Sciences. 18. 709-710 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kazuhiko Tsukagbshi, Yukihiro Shikata, Riichiro Nakajima, Masaharu Murata, and Mizuo Maeda: "Analysis of a Biopolymer by Capillary Electrophoresis with a Chemiluminescence Detector Using a Polymer solution as the Separation Medium"Analytical Sciences. 18. 1195-1198 (2002)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2004-04-14  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi