2002 Fiscal Year Final Research Report Summary
Preventive method environmental oollution bv the air-borne bacteriain dentistry clinic.
Project/Area Number |
13672170
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
矯正・小児・社会系歯学
|
Research Institution | TOKYO DENTAL COLLEGE |
Principal Investigator |
SUYAMA Yuji TOKYO DENTAL COLLEGE.Department of Dentistry. LECtURER, 歯学部, 講師 (10163065)
|
Co-Investigator(Kenkyū-buntansha) |
NAKANE Tomoo (Nihon University). LECTURER, 大学院・生産工学・研究科電気工学専攻, 講師 (30059878)
YAMADA Yuji ( Protection National Institute of Radiological Sciences) .PROFESSOR, 内部被ばく, 主任研究官 (20166739)
TAKAKU Satoru Saitama College of Health . PROFESSOR, 短期大学部, 教授 (80154764)
IKEWAKI Nobunao Kyusyu University of Health and welfare, ASSISTANT PROFESSOR, 保健学部, 助教授 (90193226)
|
Project Period (FY) |
2001 – 2002
|
Keywords | infection control / medical facility / cleanness / indoor environment / aerosol / bacteria / pollution / Dental clinic |
Research Abstract |
Since the degree of air cleanness depends on the frequency of ventilation,correction fqr the frequency of ventilationwas performed in the establishment of standards. When results of measurement of air-borne bacteria in dental clinics were evaluated according to the tolerant concentration of air-hone bacteria in the U.S. Federal Standard No. 209 B, C, D, E clean rooms,the tolerant concentration was 2.5 cfu/ft3 for class 100,000 but the concentration in the investigated dental clinics was 1.4-32.8 cfu/'ft3. According to the tolerant concentrationproposedby theAmericanAssociationof Surgery (1978), 70%of the investigated dental dines and hospitals were classified as "contaminated surgery". According to the Standards of the JapanHospital Equipment Association (1998), most hospitals were classified as quasi-clean Or general clean areas. In the classification of the degree of air cleanliness associatedwith dental treatment, weighting of thedetectionrate (%) of aandgstreptococci maybenecessary. Accordingto thesestandardswithweighting,all dental clinics investigated in this study were "in an unfavorable state". We tested the eliminating effects by the new electric air cleaner within activated carbon systemwith the plaque solution aerosol . we developed an apparatus by incorporating the bactericidal function of white coal (coal obtained by burning at 800°C or more) with a very high minus potential on its surface into an HEPA filter-type air cleaner,and carried out amodel experiment on its effects in a clean booth. Good results were obtained with an eradication rate of 90% or more for filamentous fungi, coagulase (-) staphylococci, non-fer'mentative rods,Staphylococcus aureus, Bacillus sp, Microcossus sp, Streptococcus sp, Gram-negative rods> Gram-positive rods, Gram- positive cocci, and a-hemolytic streptococci.
|