• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2004 Fiscal Year Final Research Report Summary

Development of 3D micron-CT to observe the interior of cells with high space resolving power and high-speed photograph

Research Project

Project/Area Number 13852017
Research Category

Grant-in-Aid for Scientific Research (S)

Allocation TypeSingle-year Grants
Research Field Nuclear engineering
Research InstitutionTohoku University

Principal Investigator

ISHII Keizo  Tohoku University, Graduate School of Engineering, Professor, 大学院工学研究科, 教授 (00134065)

Co-Investigator(Kenkyū-buntansha) YAMAZAKI Hiromichi  Tohoku University, Graduate School of Engineering, Associate Professor, 大学院工学研究科, 助教授 (00166654)
KIKUCHI Youhei  Tohoku University, Graduate School of Engineering, Technical Assistant, 大学院工学研究科, 教務職員 (50359535)
MATSUYAMA Shigeo  Tohoku University, Graduate School of Engineering, Research Associate, 大学院工学研究科, 助手 (70219525)
Project Period (FY) 2001 – 2004
Keywordsmicron-CT / 3D image / micro-PIXE / in-vivo / Ti-K-X-ray / visible light / ant
Research Abstract

We developed "micron-CT", using micro-PIKE for in-vivo imaging. This system comprises an X-ray CCD camera with high resolution (pixel size : 8x8μm^2, number of pixels : 1000x1000) and an X-ray point source with a spot size of 1.5x1.5μm^2 which is generated by irradiation of a microbeam on a pure metal target. The sample is placed in a tube of a small diameter, and rotated by a stepping motor. The 3D images were reconstructed from the obtained projection data by using a cone-beam CT reconstruction algorithm. We applied this micron-CT to investigate the internal structure of small ant. Ti was used as an X-ray target considering detection. efficiency of the CCD camera. An ant after formalin-fixation was inserted into a micron tube. The 3D images of ant's head were obtained with 6 μm spatial resolution and the internal structure is clearly seen. Furthermore, we developed a method to measure an ant in-vivo. The ant was anaesthetized by chloroform and then it was inserted into the micron tube. The inside of the tube is kept in atmospheric pressure and enabled to measure in-vivo. There is a large difference on the images between the fixed ant and the living one. In the case of fixed ant, the brain shrank and something was washed out due to formalin-fixation. Because the CCD is sensitive to visible light, we also examined the capability of light micron-CT using visible red lights from an Al_2O_3(Cr) ruby scintillator and applied it to investigate a small red thick. Obscure images were obtained due to the dispersion of lights. The 3D micron-CT can provide cross sectional images of in-vivo samples with high spatial resolution and will be useful for biological studies.

  • Research Products

    (6 results)

All 2005

All Journal Article (6 results)

  • [Journal Article] Development of an image reconstruction method for Micron-CT using PIXE2005

    • Author(s)
      T.Yamaguchi et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 195-202

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] MICRON-CT USING PIXE WITH MICRO-BEAMS2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 111-124

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Microbeam Analysis of Single Aerosol Particles2005

    • Author(s)
      S.Matsuyama et al.
    • Journal Title

      International Journal of PIXE 15(3&4)

      Pages: 257-262

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Microbeam Analysis at Tohoku University for Biological Studies2005

    • Author(s)
      S.Matsuyama et al.
    • Journal Title

      International Journal of PIXE 15(1&2)

      Pages: 41-46

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Contribution of Atomic Bremsstrahlung in PIXE spectra and screening effect in atomic bremsstrahlung2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      Χ-ray Spectrometry 34

      Pages: 363-365

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Contribution of Atomic Bremsstrahlung in PIXE spectra and screening effect in atomic bremsstrahlung2005

    • Author(s)
      K.Ishii et al.
    • Journal Title

      X-ray Spectrometry 34

      Pages: 363-365

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2008-05-27  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI