• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2005 Fiscal Year Final Research Report Summary

Comprehensive research concerned with the influence of flow state of artificial heart on living body by observation of microcirculation

Research Project

Project/Area Number 14104027
Research Category

Grant-in-Aid for Scientific Research (S)

Allocation TypeSingle-year Grants
Research Field Biomedical engineering/Biological material science
Research InstitutionTohoku University (2004-2005)
The University of Tokyo (2002-2003)

Principal Investigator

IMACHI Kou  Tohoku University, Biomedical Engineering Research Organization, Professor, 先進医工学研究機構, 教授 (10010076)

Co-Investigator(Kenkyū-buntansha) TAKIURA Koki  Tohoku University, Biomedical Engineering Research Organization, Associate Professor, 先進医工学研究機構, 助教授 (60375194)
YAMBE Tomoyuki  Tohoku University, Institute of Development, Aging and Cancer, Professor, 加齢医学研究所, 教授 (70241578)
ABE Yusuke  University of Tokyo, Graduate School of Medicine, Associate Professor, 大学院医学系研究科, 助教授 (90193010)
MOCHIZUKI Shuichi  University of Tokyo, Graduate School of Medicine, Instructor, 大学院医学系研究科, 助手 (00345042)
SAITO Itsuro  University of Tokyo, Research Center for Advanced Science and Technology, Instructor, 先端科学技術研究センター, 助手 (80334225)
Project Period (FY) 2002 – 2005
KeywordsCCD / Microcirculation / Artificial heart / Pulsatile flow / Continuous flow / Flow rate of erythrocyte / Circulatory control / Probe to observe microcirculation
Research Abstract

Although many types of continuous flow ventricular assist devices have become to use clinically as the bridge to heart transplantation, no body knows whether the pulsatility of blood flow is essential for living body or not. We have succeeded the basic development to solve the problem ; undulation pump AH(UPAH) and CCD probe. UPAH can change instantaneously its flow patterns by computer control of motor rotational speed. CCD probe is implantable micro-camera to observe microcirculation chronically.
The objective of this study is to clarify the necessity of pulsatility for the living body by developing more completely UPTAH and CCD probe. The following outcome has been gotten in these 4 years :
1)UPAH
Blood compatibility, durability and size & weight were improved great deal. The goat implanted UPAH survived maximally 4 months without anticoagulant. The software to control blood waveform has also been developed.
2)CCD probe
High magnification, focus adjust system and miniaturization were the objective to be developed. A micro-lens, 2 mm in diameter and 2 mm long was developed. The lens was installed into a CCD camera having 8 mm in diameter and 60 mm long. Total magnification on 14 inch TV screen was 650 times, that was enough to observe the erythrocyte flow in a capillary vessel. It could be implanted in an animal without difficulty. Residual problem is focus adjusting system.
3)Microcirculation under UPAH
The blood flow pattern was changed instantaneously from pulsatile to continuous when UPAH goat recover from surgical stress. The microcirculation was observed at bulbar conjunctiva during experiment. Following phenomena were observed until now : (1)Capillary density that is the ratio of the flowing capillaries to total capillary number, was decreased 30%. (2)The erythrocyte flow rate in the capillary was decreased 75 and some of them did not recover after the flow pattern returned to pulsatile.

  • Research Products

    (28 results)

All 2006 2005 2004 2003 2002 Other

All Journal Article (27 results) Book (1 results)

  • [Journal Article] Influence of flow design on microcirculation in condition of undulation pump-left ventricule assist device testing2006

    • Author(s)
      P.Dobsak
    • Journal Title

      Artificial Organs 30(6)

      Pages: 476-485

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Artificial heart research and present status of clinical application in Japan2006

    • Author(s)
      K.Imachi
    • Journal Title

      ASAIO Journal 52(1)

      Pages: 9-12

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Influence of flow design on microcirculation in condition of undulation pump-left ventricule assist device testing2006

    • Author(s)
      P.Dobsak, et al.
    • Journal Title

      Artificial Organs 30(6)(to be published)

      Pages: 476-485

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] An implantable probe for chronic observation of microcirculation2006

    • Author(s)
      K.Imachi, et al.
    • Journal Title

      Preceding of World Congress on Medical Physics and Biomedical Engineering (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Compact ventricular assist device and total artificial heart using undulation pump2006

    • Author(s)
      K.Imachi, et al.
    • Journal Title

      Preceding of World Congress on Medical Physics and Biomedical Engineering (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart : Effects of pulsatile and nonpulsatile flow2004

    • Author(s)
      A.Baba
    • Journal Title

      ASAIO Journal 50(4)

      Pages: 321-327

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Microcirculation of the bulbar conjunctiva in the goat implanted with a total artificial heart : Effects of pulsatile and nonpulsatile flow2004

    • Author(s)
      A.Baba, et al.
    • Journal Title

      ASAIO Journal 50(4)

      Pages: 321-327

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Progress in the control system of the undulation pump total artificial heart2003

    • Author(s)
      I.Saito
    • Journal Title

      Artificial Organs 27(1)

      Pages: 27-33

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] A study on energy supply method for a transcutaneous energy transmission system2003

    • Author(s)
      T.Ozeki
    • Journal Title

      Artificial Organs 27(1)

      Pages: 68-72

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Third model of the undulation pump total artificial heart2003

    • Author(s)
      Y.Abe
    • Journal Title

      ASAIO Journal 49(1)

      Pages: 123-127

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Advance in animal experiments with the undulation pump total artificial heart : 50 and 54 day survival periods with 1/R control2003

    • Author(s)
      Y.Abe
    • Journal Title

      ASAIO Journal 49(3)

      Pages: 325-332

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Pathophysiologic study of goats with undulation pump total artificial heart : Those that survived for more than 1 month2003

    • Author(s)
      A.Baba
    • Journal Title

      ASAIO Journal 49(4)

      Pages: 463-468

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Progress in the control system of the undulation pump total artificial heart2003

    • Author(s)
      I.Saito, et al.
    • Journal Title

      Artificial Organs 27(1)

      Pages: 27-33

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] A study on energy supply method for a transcutaneous energy transmission system2003

    • Author(s)
      T.Ozeki, et al.
    • Journal Title

      Artificial Organs 27(1)

      Pages: 67-72

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Third model of the undulation pump total artificial heart2003

    • Author(s)
      Y.Abe, et al.
    • Journal Title

      ASAIO Journal 49(1)

      Pages: 123-127

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Advance in animal experiments with the undulation pump total artificial heart : 50 and 54 day survival periods with 1/R control2003

    • Author(s)
      Y.Abe, et al.
    • Journal Title

      ASAIO Journal 49(3)

      Pages: 325-332

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Evaluation of pulsatile and nonpulsatile flow in microvessels of the bulbar conjunctiva in the goat with an undulation pump artificial heart2003

    • Author(s)
      A.Baba, et al.
    • Journal Title

      Artificial Organs 27(10)

      Pages: 875-881

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Pathophysiologic study of goats with undulation pump total artificial heart : Those that survived for more than 1 month2003

    • Author(s)
      A.Baba, et al.
    • Journal Title

      ASAIO Journal 49(4)

      Pages: 463-468

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Principle of the rotary undulation pump2002

    • Author(s)
      Y.Abe
    • Journal Title

      J Artificial Organs 5(2)

      Pages: 84-90

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Ripple reduction of the undulation pump total artificial heart2002

    • Author(s)
      I.Saito
    • Journal Title

      Artificial Organs 26(1)

      Pages: 40-44

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Durabilityu, enhancement with sufficient blood compatibility2002

    • Author(s)
      K.Iwasaki
    • Journal Title

      ASAIO Journal 48(5)

      Pages: 532-537

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Evaluation of pulsatile and nonpulsatile flow in microvessels of the bulbar conjunctiva in the goat with an undulation pump artificial heart2002

    • Author(s)
      A.Baba
    • Journal Title

      Artificial Organs 37(10)

      Pages: 875-881

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Principle of the rotary undulation pump2002

    • Author(s)
      Y.Abe, et al.
    • Journal Title

      J Artificial Organs 5(2)

      Pages: 84-90

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Ripple reduction of the undulation pump total artificial heart2002

    • Author(s)
      I.Saito, et al.
    • Journal Title

      Artificial Organs 26(1)

      Pages: 40-44

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] improved jellyfish valve : Durability enhancement with sufficient blood compatibility2002

    • Author(s)
      K.Iwasaki, et al.
    • Journal Title

      ASAIO Journal 48(5)

      Pages: 532-537

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] An implantable probe for chronic observation of microcirculation

    • Author(s)
      K.Imachi
    • Journal Title

      Proceeding of World Congress on Medical Physics and Biomedical Engineering 2006

      Pages: 2219-2223

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Compact ventricular assist device and total artificial heart using undulation pump

    • Author(s)
      K.Imachi
    • Journal Title

      Proceeding of World Congress on Medical Physics and Biomedical Engineering 2006

      Pages: 3021-3025

    • Description
      「研究成果報告書概要(和文)」より
  • [Book] 人工心臓の開発、人体にやさしい医療材料(2005第19回「大学と科学」公開シンポジウム講演収録集 (中島英雄 編))2005

    • Author(s)
      井街 宏
    • Total Pages
      215
    • Publisher
      クバプロ
    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2008-05-27  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi