• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2004 Fiscal Year Final Research Report Summary

Development of functional assessment system for dental implant in clinical use

Research Project

Project/Area Number 14380404
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field Biomedical engineering/Biological material science
Research InstitutionOKAYAMA UNIVERSITY

Principal Investigator

OKA Hisao  Okayama University, Medical School, Professor, 医学部, 教授 (80116441)

Co-Investigator(Kenkyū-buntansha) SARATANI Keiji  Osaka Dental University, Faculty of Dentistry, Lecturer, 歯学部, 講師 (60170817)
KITAWAKI Tomoki  Okayama University, Medical School, Assistant, 医学部, 助手 (40362959)
MITSUDA Takashi  Okayama University, Medical School, Assistant, 医学部, 助手 (30335591)
Project Period (FY) 2002 – 2004
Keywordsdental implant / implant stability / manual examination / assessment of implantation / osseointegration / PERIOTEST / tooth movement / mechanical mobility
Research Abstract

In order to carry out the functional evaluation of the dental implantation objectively, we have interested in the implant movement. The purpose of this study is to develop the functional assessment system for dental implant usable at the dental-chair side and to establish the index of functional assessment of the implant. We have newly developed the system in which the implant movement can be measured just after implanting to jaw bone throughout the long term and the quality of the implant operation, evaluations of the prognosis, the effects of the connection with the natural tooth, etc.can be also considered, from the functional viewpoints of the implant.
This research has been made for three years. In the first year, the standard models which simulated the movement of dental implant were made. And the measurement conditions suitable for the clinical use were examined. The functional assessment system for dental implant IAD101 and the measurement probe IAP1 were designed and produced e … More xperimentally. In the second year, the above developed system and probe and the index of functional assessment were examined. The medical safety and human interface of the probe were also examined. Finally, IAD201 and IAP2 were designed and made experimentally. In addition, the implant geometry (length and diameter) as the criteria of implant selection was also discussed by using this system and probe. In the last year, the experimental system and probe was also examined. The measuring frequency was expanded to 5000Hz in order to obtain the more accurate index of functional assessment and the tip of the probe was also miniaturized in order to improve the operability in the clinical use. Finally, the IAD301 and IAP3 were made and synthetically evaluated for clinical use, then the development of the system has been completed. The developed system will overcome various disadvantages of marketed Periotest^<TM> and Osstell^<TM>, enable the objective assessment of implantation instead of morphological radiographic examination and the manual examination, and be very effective for the evaluation of the prognosis. Moreover it will be useful in the selection of the implant geometry. Less

  • Research Products

    (8 results)

All 2004

All Journal Article (8 results)

  • [Journal Article] Development of dental implant movement (IM) checker for dental implant mobility assessment2004

    • Author(s)
      Wijaya S K, Sumikawa T, Saratani K, Kawazoe T, Oka H
    • Journal Title

      Technology and Health Care 12

      Pages: 1-13

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] インプラントの埋入深さが動揺度に及ぼす影響に関する基礎的研究2004

    • Author(s)
      澄川拓也, 岡久雄, 川添堯彬
    • Journal Title

      日本顎口腔機能学会雑誌 10

      Pages: 1-10

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Development of implant movement checker for determining dental implant stability2004

    • Author(s)
      Wijaya S K, Oka H, Saratani K, Sumikawa T, Kawazoe T
    • Journal Title

      Medical Engineering & Physics 26

      Pages: 513-522

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Assessment of Dental Implant Geometry based on Implant Movement2004

    • Author(s)
      Oka H, Wijaya S K, Sumikawa T, Saratani K, Kawazoe T
    • Journal Title

      生体医工学シンポジウム2004

      Pages: 160-165

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Development of dental implant movement(IM) checker for dental implant mobility assessment2004

    • Author(s)
      Wijaya SK, Sumikawa T, Saratani K, Kawazoe T, Oka H
    • Journal Title

      Technology and Health Care 12

      Pages: 1-13

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Effect of the length of an implant embedded in bone on mobility2004

    • Author(s)
      Sumikawa T, Oka H, Kawazoe T
    • Journal Title

      J.Jpn.Soc.Stomatognath.Funct. 10

      Pages: 141-150

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Development of implant movement checker for determining dental implant stability2004

    • Author(s)
      Wijaya SK, Oka H, Saratani K, Sumikawa T, Kawazoe T
    • Journal Title

      Medical Engineering & Physics 26

      Pages: 513-522

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Assessment of Dental Implant Geometry based on Implant Movement2004

    • Author(s)
      Oka H, Wijaya SK, Sumikawa T, Saratani K, Kawazoe T
    • Journal Title

      JSMBE Symposium 2004

      Pages: 160-165

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2006-07-11  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi