2003 Fiscal Year Final Research Report Summary

Establishment of clinical safety in monitor diagnosis of breast cancer from the viewpoint of medical image perception

Research Project

Project/Area Number 14570849
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionNagoya University

Principal Investigator

SHIMAMOTO Kazuhiro  Nagoya University, School of Medicine, Professor, 医学部, 教授 (70178961)

Co-Investigator(Kenkyū-buntansha) IKEDA Mitsuru  Nagoya University, University Hospital, Associate Professor, 医学部附属病院, 助教授 (50184437)
Project Period (FY) 2002 – 2003
KeywordsBreast, neoplasm / Image perception / Monitor diagnosis / Ultrasonography, mammary / Mammography / Radiography, digital / Kappa statistics / Observer variation
Research Abstract

(1)Interobserver agreement in quality control of mammography was evaluated using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS Model X) by four viewing methods : (1)original screen-film (SF), (2)soft-copy reading of the digitized film image, (3)hard-copy reading of computed radiography using imaging plate (FCR), and (4)soft-copy reading of FCR. 11 radiologists judged each item of the phantom using a three-point rating scale. With regard to "mass" depiction, kappa value of FCR was significantly lower than that of SF (p<0.05). There was no significant difference in kappa value for detecting "microcalcifications". However, score of "microcalcifications" by FCR hard-copy reading was significantly lower than that by the other three viewing methods (p<0.05). Viewing methods could affect the judgment of the phantom image, and special attention to viewing conditions are recommended for quality control of FCR mammogram.
(2)Significance of internal echoes at interpretation of breast US image was evaluated 100 breast masses (50 benign,50 malignant) were interpreted by 6 radiologists and 20 radiological technologists using a four-point rating scale. Double reading was done in 50 cases. US images were modified to make the internal echoes invisible by painting with black color using the Adobe Photoshop. ROC analysis showed a significant difference in diagnostic performance between the original US images and modified US images (p<0.05). Kappa value of posterior echoes was highest whereas that of halo showed the lowest value in both the original and modified images. Reproducibility in halo and gland surface was fair, and that in posterior echoes and the D/W was good. The internal echoes are important for image perception of breast lesions. Lack of internal echoes should degrade the diagnostic performance of breast US.

  • Research Products

    (14 results)

All Other

All Publications (14 results)

  • [Publications] 島本 佳寿広: "画像診断最適モニタの条件"新医療. 30・9. 111-113 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Mitsuru Ikeda: "Influence of monitor luminance change on observer performance for detection of abnormalities"Investigative Radiology. 38・1. 57-63 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiro Shimamoto: "Interobserber agreement and performance score comparison in quality control using a breast phantom : screen-film mammography versus computed radiography."European Radiology. 12・9. 2192-2197 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Mitsuru Ikeda: "Statistical method in a comparative study in which the standard treatment is superior to others."Nagoya Journal of Medical Science. 65・(3,4). 127-132 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Shunichi Ishihara: "CRT diagnosis of pulmonary disease : influence of monitor brightness and room illuminance on observer performance."Computerized Medical Imaging and Graphics. 26・1. 181-185 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 佐竹弘子: "マルチスライスCTによる乳癌の診断"映像情報(M). 34・3. 312-317 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] 島本佳寿広: "乳癌の画像診断の定量化とCADへの展開"映像情報(M). 34・3. 318-322 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Kazuhiro Shimamoto: "Optimal monitor for medical diagnosis"New Medicine in Japan. 30-9. 111-113 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Mitsuru Ikeda: "Influence of monitor luminance change on observer performance for detection of abnormalities"Investigative Radiology. 38-1. 57-63 (2003)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kazuhiro Shimamoto: "Interobserber agreement and performance score comparison in quality control using a breast phantom : screen-film mammography versus computed radiography."European Radiology. 12-9. 2192-2197 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Mitsuru Ikeda: "Statistical method in a comparative study in which the standard treatment is superior to others."Nagoya Journal of Medical Science. 65-3/4. 127-132 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Shunichi Ishihara: "CRT diagnosis of pulmonary disease : influence of monitor brightness and room illuminance on observer performance"Computerized Medical Imaging and Graphics. 26-1. 181-185 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Kazuhiro Shimamoto: "Quantification of breast cancer imaging diagnosis and introduction of computer-aided diagnosis (CAD)"A monthly Journal of Medical Imaging and Information. 34-3. 318-322 (2002)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hiroko Satake: "Breast cancer diagnosis by MSCT"A monthly Journal of Medical Imaging and Information. 34-3. 312-317 (2002)

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2005-04-19  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi