2003 Fiscal Year Final Research Report Summary

Study on the dose distribution measurement precision in the radiotherapy using GAFchromic film

Research Project

Project/Area Number 14570859
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionOKAYAMA UNIVERSITY

Principal Investigator

AZUMA Yoshiharu  Okayama University, Medical School, Associate Professor, 医学部, 助教授 (90212505)

Co-Investigator(Kenkyū-buntansha) GOTO Sachiko  Okayama University, Medical School, Research Associate, 医学部, 助手 (80243517)
NAKAGIRI Yoshitada  Okayama University, Medical School, Associate Professor, 医学部, 助教授 (80207745)
Project Period (FY) 2002 – 2003
KeywordsRadiotherapy / Dose distribution / Film type dose meter / Gafchromic film / Measurement precision
Research Abstract

In the radiotherapy field, a complicated dose distribution must be evaluated and it is required that dose assessment should have the high precision. As the radiometer that performs dose distribution assessment of 2-dimensional one, Radiochromic film is developed and attracts attention. The density ununiformity of the film and the matching with the film and a density-measuring instrument are directly involved in a measurement error directly. Then, while investigating about the ununiformity of the density of the film in this study, the influence, which the optical density before irradiation has on the density after irradiation, was analyzed, and the correction procedure of he influence was considered. First, to dosimetry system, which consists of Laser Densitometer Model 1710 for an x-ray film and Gafchromic film MD-55-2, the check of density measurement precision was performed and the existence of the artifact by the formation, of a 2-dimensional picture of density data was observed in 1-60 Gy. Consequently, in case where the measurement precision in highly detailed pixel level is required, such as performing complicated dose distribution assessment in 3D-CRT or IMRT, it was thought to be necessary to add further the correction process of density ununiformity that is represented by double exposure technique. Furthermore, it turned out that the sample pixel value after irradiation also becomes high as the sample pixel value before irradiation became high. Moreover, since the linear approximation, was possible in the relation between both sample pixel values, the procedure of creating conversion curve of an absorbed dose to a pixel value for every sample pixel value before each irradiation, and correcting the sample pixel value after irradiation was adopted. By this procedure, the measurement result higher than the measurement performed only with the conventional conversion curve of an absorbed dose to a pixel value for precision could be obtained.

  • Research Products

    (2 results)

All Other

All Publications (2 results)

  • [Publications] 青山 英樹: "X線エネルギーの違いによる早期声門癌治療の吸収線量評価-フィルムタイプ線量計を用いた検討-"日本放射線腫瘍学会誌. 14・4. 239-245 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Hideki Aoyama: "The absorbed dose evaluation of the radiation therapy of the early glottic cancer by the difference in X-rays energy 'Investigation with the film type dosimeter'"The Journal of JASTRO. Vol.14 No.4. 239-245 (2002)

    • Description
      「研究成果報告書概要(欧文)」より