Study of medical imaging of X-ray minute point source using synchrotron radiation

Research Project

Project/Area Number 14570899
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionJapan Synchrotron Radiation Research institute

Principal Investigator

YAMASAKI Katsuhito  Japan Synchrotron Radiation Research institute, Life & Environmental Sci.Div., Associate Chief Scientist, 利用研究促進部門II・医学チーム・チームリーダー, 副主席研究員 (50210381)

Co-Investigator(Kenkyū-buntansha) SUGIMURA Kazuro  Kobe Uni., Grad.Sch.of Med., Prof., 大学院・医学研究科・生体情報講座, 教授 (00136384)
TSUSAKA Yoshiyuki  Uni.of Hyogo, Grad.Sch.of Material, Asso.Prof., 理学部, 助手 (20270473)
KAGOSHIMA Yasushi  Uni.of Hyogo, Grad.Sch.of Material, Prof., 理学部, 助教授 (10224370)
SHIKATA Yoshihiro  Meijo Univ., Faculty of Sci. & Tech., Prof., 理工学部, 教授 (50028114)
UMETANI Keiji  Japan Synchrotron Radiation Research institute, Life & Environmental Sci.Div., Senior Scientist, 利用研究促進部門II・医学チーム, 主幹研究員 (50344396)
Project Period (FY) 2002 – 2003
KeywordsRay Tracing method / Microfocus X-ray / Refraction contrast imaging
Research Abstract

1.Radiation dose was calculated for microangiography by absorption imaging using parallel X-ray beam. These results were in press Radiation Medicine.
2.A Nobel method of detecting margin in X-ray imaging was invented. These results were published in Igakubutsuri.
3.Osteocyte, osteoblast and fine structure of bone tissue were observed using parallel X-ray beam. These results were published in Radiation Medicine.
4.Simulation program was developed to evaluate contrast of obstacle using X-ray tracing method. Contrasts of refraction contrast imaging were compared with those of absorption imaging. These results were in press Radiation Medicine.
5.Imaging experiment was performed using Pt.Needle.
6.Interfernce of refraction pattern of overlapping obstacles was simulated. The condition of speckle pattern was calculated in this method. These results were in press Radiation Medicine.

  • Research Products

    (4 results)

All Other

All Publications (4 results)

  • [Publications] 平野雅嗣, 山崎克人, 櫻井孝, 近藤威, 劉嘉忠, 片渕哲朗, 田村進一 他: "血管造影像におけるX線屈折コントラスト効果を利用した血管径計測"医学物理. 23・2. 157-159 (2002)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] M.Hirano, K.Yamasaki, R.Kitazawa, K.Sugimura, S.Tamura, et al.: "Imaging of fine structure of bone sample with high coherent X-ray beam and high spatial resolution detector"Radiation Medicine. 22・1. 246-249 (2003)

    • Description
      「研究成果報告書概要(和文)」より
  • [Publications] Hirano M, Yamasaki K, Kitazawa R, Kitazawa S, Okada H, Katafuchi T, Sakurai T, Kondoh T, Ohbayshi C, Maeda S, Sugimura K, Tamura S: "Imaging of fine structure of bone sample with high coherent X-ray beam and high spatial resolution detector"Radiat Med.. 22-1. 56-9 (2004)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Publications] Hirano K, Yamasaki K, Sakurai T, Kondoh T, Ryu Y, Okada H, Sugimura K, Kitazawa R, Maeda S, Katafuchi T, Tamura S: "Measurement of blood vessel diameter for angiography using refraction contrast imaging"Igaku Butsuri. 23-2. 157-9 (2003)