2003 Fiscal Year Final Research Report Summary
Study of medical imaging of X-ray minute point source using synchrotron radiation
Project/Area Number |
14570899
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Radiation science
|
Research Institution | Japan Synchrotron Radiation Research institute |
Principal Investigator |
YAMASAKI Katsuhito Japan Synchrotron Radiation Research institute, Life & Environmental Sci.Div., Associate Chief Scientist, 利用研究促進部門II・医学チーム・チームリーダー, 副主席研究員 (50210381)
|
Co-Investigator(Kenkyū-buntansha) |
SUGIMURA Kazuro Kobe Uni., Grad.Sch.of Med., Prof., 大学院・医学研究科・生体情報講座, 教授 (00136384)
TSUSAKA Yoshiyuki Uni.of Hyogo, Grad.Sch.of Material, Asso.Prof., 理学部, 助手 (20270473)
KAGOSHIMA Yasushi Uni.of Hyogo, Grad.Sch.of Material, Prof., 理学部, 助教授 (10224370)
SHIKATA Yoshihiro Meijo Univ., Faculty of Sci. & Tech., Prof., 理工学部, 教授 (50028114)
UMETANI Keiji Japan Synchrotron Radiation Research institute, Life & Environmental Sci.Div., Senior Scientist, 利用研究促進部門II・医学チーム, 主幹研究員 (50344396)
|
Project Period (FY) |
2002 – 2003
|
Keywords | Ray Tracing method / Microfocus X-ray / Refraction contrast imaging |
Research Abstract |
1.Radiation dose was calculated for microangiography by absorption imaging using parallel X-ray beam. These results were in press Radiation Medicine. 2.A Nobel method of detecting margin in X-ray imaging was invented. These results were published in Igakubutsuri. 3.Osteocyte, osteoblast and fine structure of bone tissue were observed using parallel X-ray beam. These results were published in Radiation Medicine. 4.Simulation program was developed to evaluate contrast of obstacle using X-ray tracing method. Contrasts of refraction contrast imaging were compared with those of absorption imaging. These results were in press Radiation Medicine. 5.Imaging experiment was performed using Pt.Needle. 6.Interfernce of refraction pattern of overlapping obstacles was simulated. The condition of speckle pattern was calculated in this method. These results were in press Radiation Medicine.
|
Research Products
(4 results)
-
-
-
[Publications] Hirano M, Yamasaki K, Kitazawa R, Kitazawa S, Okada H, Katafuchi T, Sakurai T, Kondoh T, Ohbayshi C, Maeda S, Sugimura K, Tamura S: "Imaging of fine structure of bone sample with high coherent X-ray beam and high spatial resolution detector"Radiat Med.. 22-1. 56-9 (2004)
Description
「研究成果報告書概要(欧文)」より
-
[Publications] Hirano K, Yamasaki K, Sakurai T, Kondoh T, Ryu Y, Okada H, Sugimura K, Kitazawa R, Maeda S, Katafuchi T, Tamura S: "Measurement of blood vessel diameter for angiography using refraction contrast imaging"Igaku Butsuri. 23-2. 157-9 (2003)
Description
「研究成果報告書概要(欧文)」より