• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2005 Fiscal Year Final Research Report Summary

Investigation of the removable partial denture design based on the in vivo 3-D force analyses on the abutment tooth of the removable partial denture

Research Project

Project/Area Number 15390583
Research Category

Grant-in-Aid for Scientific Research (B)

Allocation TypeSingle-year Grants
Section一般
Research Field 補綴理工系歯学
Research InstitutionTOHOKU UNIVERSITY

Principal Investigator

SASAKI Keiichi  Tohoku University, Graduate School of Dentistry, Professor, 大学院・歯学研究科, 教授 (30178644)

Co-Investigator(Kenkyū-buntansha) KURIYAGAWA Tsunemoto  Tohoku University, Graduate School of Engineering, Professor, 大学院・工学研究科, 教授 (90170092)
INAI Tetsuji  Tohoku University, Hospital, Lecturer, 病院・講師 (60193538)
KOYAMA Shigeto  Tohoku University, Hospital, Lecturer, 病院・講師 (10225089)
KAWATA Tetsuo  Tohoku University, Graduate School of Dentistry, Assistant Professor, 大学院・歯学研究科, 助手 (80292225)
Project Period (FY) 2003 – 2005
Keywordspartial denture / abutment tooth / piezo-electric transducer / load measurement / 3-dimensional
Research Abstract

The purpose of this study is to clarify the behavior of the load applied to the abutment tooth by means of the 3-dimensional force measuring device with a piezo-electric transducer that we have developed. It is important to know that load for partial denture design including the selection of the abutment tooth and occlusal scheme. The custom-made force measuring device comprised an inner part forming a metal core, a force transducer, and an outer part forming a metal crown.
The subjects were a young male with natural dentition and an old female with partial edentulous dentition. Informed consent was obtained after full explanation of this study. The experimental teeth were the maxillary left second molar of dentulous subject and mandibular right second premolar of partial edentulous subject.
When the partial edentulous subject wearing the denture with distal rest clenched maximally, the magnitude of the load applied to the abutment tooth decreased significantly than without the denture. When the partial edentulous subject wearing the denture with medial rest clenched maximally, the angle of the load direction was decreased significantly than without the denture. On the other hand, there was significant difference between the angles with the medial rest and with the distal rest. When the partial edentulous subject wearing the denture with distal rest clenched maximally, the angle of the load direction was increased significantly than the denture with medial rest. The force vector with the medial and distal rests directed most laterally, and that with the medial rest directed most downward. There was not significant difference among the directions of four different conditions in the frontal plane.
In the dentulous subject, The maximum magnitude was 173.3±15.3N during MVC. As the magnitude of the compressive force increased, the load direction changed three dimensionally. Tractive forces were recorded throughout the chewing the sticky food.

  • Research Products

    (6 results)

All 2006 2005 2003

All Journal Article (6 results)

  • [Journal Article] In vivo 3-dimensional measurement of the force exerted on a tooth during clenching2006

    • Author(s)
      T Kawaguchi, T Kawata, T Kuriyagawa, K Sasaki
    • Journal Title

      J Biomech (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] In vivo 3-Dimensional Force Measurement in Teeth during Functions2005

    • Author(s)
      N Yoda, T Kawata, H Suenaga, T Kuriyagawa, K Sasaki
    • Journal Title

      J Dent Res (In press)

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] In vivo 3-dimensional measurement of the force exerted on a tooth during clenching2005

    • Author(s)
      T Kawaguchi, T Kawata, T Kuriyagawa, K Sasaki
    • Journal Title

      J Biomech (In press)

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] In vivo 3-Dimensional Force Measurement in Teeth during Functions2005

    • Author(s)
      Yoda N, Kawata T, Suenaga H, Kuriyagawa T, Sasaki K
    • Journal Title

      J Dent Res (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] 小型水晶圧電式センサによる部分床義歯支台歯の荷重測定2003

    • Author(s)
      川口威史, 川田哲男, 佐々木啓一, 厨川常元
    • Journal Title

      補綴誌 47・109

      Pages: 69

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] In vivo Force Measurement in Abutment Tooth of Partial Denture with Piezo-electric Transducer2003

    • Author(s)
      Kawaguchi T, Kawata T, Sasaki K, Kuriyagawa T
    • Journal Title

      Japan Prosthodontic Society 69

      Pages: 47-109

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2007-12-13  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi