• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2004 Fiscal Year Final Research Report Summary

Viscosity Sensor of a Phase Detection Type

Research Project

Project/Area Number 15560366
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Measurement engineering
Research InstitutionNihon University

Principal Investigator

KOBAYASHI Tsutomu  Nihon University, College of Engineering, Professor, 工学部, 教授 (60059699)

Co-Investigator(Kenkyū-buntansha) KIDA Takuro  Nihon University, College of Engineering, Professor, 工学部, 教授 (90016535)
TAI Hidekazu  Nihon University, College of Engineering, Lecturer, 工学部, 講師 (20246846)
Project Period (FY) 2003 – 2004
KeywordsViscosity sensor / Viscometer of vibration type / Triangular bimorph transducer / Phase detection sensor / Phase difference type viscometer / High viscosity measurement
Research Abstract

A conventional viscometer requires a large amount of specimen liquid for viscosity measurement. Furthermore, measurement and handling of high viscosity are troublesome. To solve these problems, we used a piezoelectric bimorph transducer, processed like a triangle. It was utilized as two unimorphs : one was used for driving, and the other was used for detection. A new original viscometer was thereby developed that detects the viscosity load as an electric phase difference between two unimorphs. The rectangular bimorph was processed into a triangle to heighten the detection of the phase difference for viscosity. The phase difference appears only slightly in a general rectangular bimorph. The triangular configuration is an important and novel improvement. Moreover, the resonance frequency is generally used as the drive frequency of this bimorph. However, the frequency of the non-resonance range which the phase characteristic was steady was used in this research. This is also an original f … More eature of this experiment.
Results obtained to date confirm measurement of low viscosity using frequencies of 200-500 Hz. Then, a non-resonant frequency band of 100 Hz or less, which is lower than the first resonance frequency of the bimorph, is used especially to attempt high-viscosity measurements. In this study, drooping characteristics occasionally appeared for the phase difference according to the length of the bimorph used. We spent much time to clarify that phenomenon. Finally, the problem was solved. Clarification of its cause improved the results and introduced the possibility of the device's practical use. Because the phase difference was used in the experiments, it was possible to measure high viscosities using a low frequency. Moreover, the use of such a low frequency is a novel feature among viscometers. This viscometer allows easy measurements in real time using a small amount of liquid. It can measure very high viscosities that are troublesome to measure using conventional devices. Consequently, it can be utilized conveniently for manufacturing management purposes including basic research of materials in general and food industries. Less

  • Research Products

    (19 results)

All 2005 2004 2003

All Journal Article (19 results)

  • [Journal Article] 三角形圧電バイモルフを用いた位相型の粘度センサ-高粘度測定時のセンサ特性-2005

    • Author(s)
      田井 秀一, 小林 力
    • Journal Title

      圧電材料・デバイスシンポジウム2005

      Pages: 103-108

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 三角形圧電バイモルフ振動子を用いた振動型粘度計-高粘度測定時の温度特性-2005

    • Author(s)
      本田 智, 田井 秀一, 小林 力
    • Journal Title

      日本音響学会研究発表会講演論文集 3月

      Pages: 989-990

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Vibration-type viscometer using a triangular bimorph transducer. -Temperature characteristics in measurements of high viscosity-2005

    • Author(s)
      S.Honda, H.Tai, T.Kobashi
    • Journal Title

      Spring Meet.Acoust.Soc.Jpn.

      Pages: 989-990

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Phase difference type viscosity sensor using a triangular piezoelectric bimorph -sensor characteristics in measuring high viscosity-2005

    • Author(s)
      H.Tai, T.Kobayashi
    • Journal Title

      Piezoelectric Materials & Device Symposium 2005

      Pages: 103-108

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibration-type viscometer using triangular bimorph transducer -measurement of high viscosity by low-frequency operation-2004

    • Author(s)
      H.Tai, J.Seki, T.Kida, T.Kobayashi
    • Journal Title

      Japanese Journal of Applied Physics 43.5B

      Pages: 3088-3089

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 三角形圧電バイモルフ振動子を用いた振動型粘度計2004

    • Author(s)
      田井 秀一, 小林 力
    • Journal Title

      超音波TECHNO 16[5]

      Pages: 96-100

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 振動型粘度計用の三角形圧電バイモルフ振動子の高粘度測定時の位相差特性について2004

    • Author(s)
      田井 秀一, 小林 力
    • Journal Title

      日本音響学会研究発表会講演論文集 9月

      Pages: 1243-1244

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Phase Difference Characteristics of Triangular Bimorph Transducer in Vibrating Viscometer Used for High Viscosity Measurement.2004

    • Author(s)
      H.Tai, T.Kobayashi
    • Journal Title

      Autumn Meet.Acoust.Soc.Jpn.

      Pages: 1243-1244

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibration-type viscometer using triangular bimorph transducer-measurement of high viscosity by low-frequency operation-2004

    • Author(s)
      H.Tai, J.Seki, T.Kida, T.Kobayashi
    • Journal Title

      Jpn.J.Appl.Phys. 43[No.5B]

      Pages: 3088-3089

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibro-viscometer using a triangular bimorph transducer2004

    • Author(s)
      T.Kobayashi, H.Tai
    • Journal Title

      Tyouonpa techno (Japan Industrial Publishing)

      Pages: 96-100

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibration characteristics of the triangular bimorph transducer for a vibrating viscometer.2004

    • Author(s)
      H.Tai, K.Aoki, T.Kobayashi
    • Journal Title

      Spring Meet.Acoust.Soc.Jpn.

      Pages: 971-972

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Preparation and characterization of (Pb,La)(Zr,Ti) O_3 composites2003

    • Author(s)
      K.Tsuzuki, T.kobayashi
    • Journal Title

      Japanese Journal of Applied Physics 42.9B

      Pages: 6027-6032

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Broadband transducer for diagnostics using a plano-concave ultrasonic transducer driven by chirp wave2003

    • Author(s)
      H.Tai, T.Kobayashi
    • Journal Title

      Japanese Journal of Applied Physics 42.5B

      Pages: 3031-3035

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 三角形圧電バイモルフ振動子を用いた振動型粘度計-粘度の低周波による測定-2003

    • Author(s)
      関, 本多, 田井, 木田, 小林
    • Journal Title

      日本音響学会秋季研究発表会講演論文集

      Pages: 1023-1024

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 三角形圧電バイモルフ振動子を用いた振動型粘度計-低周波駆動による高粘度の測定-2003

    • Author(s)
      田井, 関, 木田, 小林
    • Journal Title

      超音波エレクトロニクスの基礎と応用に関するシンポジウム 24

      Pages: 107-108

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Preparation and Characterization of (Pb,La)(Zr,Ti)O_3 Composites(9/65/35〜6/65/35)2003

    • Author(s)
      K.Tsuzuki, T.Kobayashi
    • Journal Title

      Jpn.J.Appl.Phys. 42, Part 1

      Pages: 6027-6032

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibration type viscometer using a triangular bimorph transducer -Viscosity measurement by low frequency-2003

    • Author(s)
      J.Seki, H.Tai, T.Kobayashi
    • Journal Title

      Autumn Meet.Acoust.Soc.Jpn.

      Pages: 1023-1024

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Vibration type viscometer using a triangular bimorph transducer - High viscosity measurement by low frequency -2003

    • Author(s)
      H.Tai, J.Seki.T.Kida, T.Kobayashi
    • Journal Title

      The 24^<th> Symposium on ultrasonic electronics

      Pages: 107-108

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Broadband transducer for diagnostics using a plano-concave ultrasonic transducer driven by chirp wave2003

    • Author(s)
      H.Tai, T.Kobayashi
    • Journal Title

      Jpn.J.Appl.Phys. 42, Part 1, No.5B

      Pages: 3031-3035

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2006-07-11  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi