2004 Fiscal Year Final Research Report Summary

Seismic design of steel building with H-section columns and energy absorbing elements

Research Project

Project/Area Number 15560485
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Building structures/materials
Research InstitutionChiba University

Principal Investigator

MORITA Koji  Chiba University, Faculty of Engineering, Professor, 工学部, 教授 (20057227)

Co-Investigator(Kenkyū-buntansha) HARADA Yukihiro  Chiba University, Graduate School of Science and Technology, Associate Professor, 大学院・自然科学研究科, 助教授 (10272791)
Project Period (FY) 2003 – 2004
KeywordsH-section column / Strong axis column / Weak axis column / High-strength bolted tensile connection / Subassemblage test / Energy absorption / Seismic design
Research Abstract

The purpose of this research is to experimentally investigate structural behavior of a steel framework with H-section columns and semi-rigid beam-end connections. This research will help to promote mechanically and economically rational seisimic design of steel buildings using H-section columns. The conclusions of this research are summarized as follows.
1.Structural behaviors of flange-split-T and web-split-T tensile connections are experimentally investigated by tensile loading tests. Observed full plastic strength and ultimate strength of the connections can be estimated well by plastic analysis.
2.Structural behavior of a subassemblage with flange-split-T semi-rigid moment connections is experimentally investigated by cyclic loading tests. The tensile connection behavior in the subassemblage specimen is in good agreement with that in the tensile specimens ; this indicates that the structural behavior of steel frameworks with the flange-split-T semi-rigid moment connections can be predicted by using the knowledge about the flange-split-T tensile connections. It is also observed at the subassemblage loading test that flat plates in a panel zone and angle members at the flange attached with high-strength bolts show good out-of-plane reinforcement effect on plate elements in the H-section columns.
3.Stmctural behavior of a subassemblage with web-split-T moment connections is experimentally investigated by cyclic loading test. The tensile connection behavior in the subassemblage specimen is in good agreement with that in the tensile specimens; this is the same as the flange-split-T connections.

  • Research Products

    (4 results)

All 2005 2004

All Journal Article (4 results)

  • [Journal Article] 柱梁接合部がスプリットティ形式高力ボルト引張接合部で構成されるH形強軸柱-H形梁骨組の力学的挙動に関する実験的研究2005

    • Author(s)
      新垣忠志, 原田幸博, 森田耕次
    • Journal Title

      鋼構造論文集 第12巻46号(掲載予定)

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Experimental Study on Structural Behavior of Steel Framework Having H-Section Beam-to-H-Section Column Connections with Split-T Tensile Connections2005

    • Author(s)
      Tadashi Arakaki, Yukihiro Harada, Koji Morita
    • Journal Title

      Steel Construction Engineering Vol.12, No.46(scheduled to publish)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] H形鋼スプリットティ・高力ボルト接合部の引張耐力に関する研究2004

    • Author(s)
      江波戸和正, 森田耕次, 照沼美穂, 野本篤史
    • Journal Title

      鋼構造論文集 第11巻第42号

      Pages: 41-54

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Tensile Strength of Tension Type High Strength Bolted Connection between Wide Flange Section and Split-T2004

    • Author(s)
      Kazumasa Ebato, Koji Morita, Miho Terunuma, Atsushi Nomoto
    • Journal Title

      Steel Construction Engineering Vol.11, No.42

      Pages: 41-52

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2006-07-11  