• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2004 Fiscal Year Final Research Report Summary

Development and evaluation of imaging systems for the three-dimensional structure of arteries using synchrotron radiation monochromatic X-rays

Research Project

Project/Area Number 15591312
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Radiation science
Research InstitutionHIGH ENERGY ACCELERATOR RESEARCH ORGANIZATION (2004)
The High Energy Accelerator Research Organization (2003)

Principal Investigator

HYODO Kazuyuki  HIGH ENERGY ACCELERATOR RESEARCH ORGANIZATION, Institute of materials structure science, Assistant, 物質構造科学研究所, 助手 (60201729)

Co-Investigator(Kenkyū-buntansha) ANDO Masami  HIGH ENERGY ACCELERATOR RESEARCH ORGANIZATION, Institute of materials structure science, Professor, 物質構造科学研究所, 教授 (30013501)
OTSUKA Sadanori  University of Tsukuba, Institute of clinical sciences, Lecturer, 臨床医学系, 講師 (40241814)
Project Period (FY) 2003 – 2004
Keywordssynchrotron radiation / monochromatic X-ray / monochromator / angiography / three-dimensional structure / coronasry artery / K-edge / K吸収端
Research Abstract

Synchrotron radiation, which is characterized by its high intensity, X-ray energy tunability and small X-ray beam divergence, is a very powerful tool for medical researches and many imaging systems using synchrotron radiation are under developing in synchrotron radiation facilities in the world. In those systems, the irradiation direction of monochromatic X-rays to an object is limited by characteristics of generating synchrotron radiation beam from an accelerator. Therefore, there is a case in which it becomes a problem, when the overlap of arterial system and soft tissues make an X-ray projection image. It seems to be very useful to obtain information of the three-dimensional structure of the target organ, especially in case of angiography using synchrotron radiation monochromatic X-rays. The purpose of this study is development and evaluation of the method for reducing the overlap of the cardiovascular system in an X-ray projection image by (1) rotating an object and (2) using a Laue crystal. Preliminary experiments on the stereo-imaging were performed to determine the three-dimensional structure of coronary arteries for intravenous coronary angiography and micro-angiography using synchrotron radiation produced by a bending magnet and a multi-pole wiggles beamlines at the PF-AR, KEK and a vertical wiggler beamline at the PF, KEK. The possibility of these two methods was confirmed by the phantom experiments. It is expected that the result can be applied to the other imaging methods using synchrotron radiation monochromatic X-rays including the diffraction enhancement imaging (DEI) method.

  • Research Products

    (11 results)

All 2005 2004 2003 Other

All Journal Article (10 results) Book (1 results)

  • [Journal Article] Improvement of X-ray image quality for medical applications using synchrotron radiation monochromatic X-rays2005

    • Author(s)
      Kazuyuki HYODO
    • Journal Title

      European Radiology 15(1)

      Pages: 306

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Improvement of X-ray image quality for medical applications Using synchrotron radiation monochromatic X-rays2005

    • Author(s)
      Kazuyuki HYODO, et al.
    • Journal Title

      European Radiology 15(1)

      Pages: 206

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Improvement of X-ray image quality for medical applications2004

    • Author(s)
      Kazuyuki HYODO
    • Journal Title

      BSR2004 Abstract

      Pages: 63

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Improvement of X-ray image quality for medical applications2004

    • Author(s)
      Kazuyuki HYODO, et al.
    • Journal Title

      Biology and Synchrotron Radiation 2004 63

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] 放射光単色X線による血管造影検査システムの開発2003

    • Author(s)
      兵藤一行
    • Journal Title

      原子力研究会 NE03

      Pages: 19-22

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 放射光単色X線を用いたイメージング法の開発2003

    • Author(s)
      兵藤一行
    • Journal Title

      化学放射線治療科学研究会 抄録 1

      Pages: 9-13

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 放射光血管造影2003

    • Author(s)
      大塚定徳
    • Journal Title

      化学放射線治療科学研究会 抄録 1

      Pages: 31-35

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] 放射光単色X線を用いた医用画像に関する診断能の向上について2003

    • Author(s)
      兵藤一行
    • Journal Title

      医学物理 23.3

      Pages: 131-132

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] On the improvement of the diagnosability on medical images(in Japanese)2003

    • Author(s)
      Kazuyuki HYODO, et al.
    • Journal Title

      Japanese Journal of Medical Physics 23(3)

      Pages: 131-132

    • Description
      「研究成果報告書概要(欧文)」より
  • [Journal Article] Overview of clinical intravenous coronary angiography both in Japan and ESRF

    • Author(s)
      Sadanori Ohtsuka, et al.
    • Journal Title

      Nuclear Instrument and method 2005 (in press)

    • Description
      「研究成果報告書概要(欧文)」より
  • [Book] NSA/COMMENTARIES : NO.11 放射線と先端医療技術2003

    • Author(s)
      古林 徹, 岡本浩一 編集(分担執筆 兵藤一行)
    • Total Pages
      205
    • Publisher
      日本原子力産業会議 原子力システム研究懇話会
    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2006-07-11  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI

Powered by NII kakenhi