2017 Fiscal Year Final Research Report
Adaptation of a new regenerator structure aiming at the high performance and efficiency for cryocoolers
Project/Area Number |
15K06693
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Energy engineering
|
Research Institution | Oshima National College of Maritime Technology |
Principal Investigator |
Masuyama Shinji 大島商船高等専門学校, その他部局等, 教授 (00287591)
|
Co-Investigator(Kenkyū-buntansha) |
沼澤 健則 国立研究開発法人物質・材料研究機構, その他部局等, その他研究員 (30354319)
|
Project Period (FY) |
2015-04-01 – 2018-03-31
|
Keywords | 極低温 / 小型冷凍機 / 蓄冷器 |
Outline of Final Research Achievements |
An equivalent changing method of regenerator configuration was applied to a Gifford-McMahon (GM) cryocooler. The evaluation tests have been carried out at 4 K level. The experimental result proved that the cooling power at 4.2 K was able to improve when the warm-end side of the second stage regenerator of GM cryocooler was made narrow equivalently. The numerical analysis showed that the density of helium gas is much different between the warm- and cold-end side within the regenerator. From this study, the elucidation of regenerator characteristic that can achieve a high performance cryocooler progressed.
|
Free Research Field |
低温工学
|