2005 Fiscal Year Final Research Report Summary

Development of an anastomotic device for distal anastomosis to achieve marked improvement of total arch replacement

Research Project

Project/Area Number 16500312
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Medical systems
Research InstitutionChiba University

Principal Investigator

IMAMAKI Mizuho  Chiba University, Hospital, assistant professor, 医学部附属病院, 講師 (40241088)

Co-Investigator(Kenkyū-buntansha) SHIMURA Hitoshi  Chiba University, Hospital, assistant professor, 医学部附属病院, 助手 (90312941)
Project Period (FY) 2004 – 2005
Keywordsarch aneurysm / less invasive surgery / graft replacement / anastomotic device
Research Abstract

[Purpose]To achieve marked improvement of graft replacement for aortic arch aneurysm, distal anastomosis must be performed without hemorrhage and in a short time. We developed an anastomotic device for distal anastomosis and conducted a basic experiment to confirm its efficacy. [Methods]The anastomotic device has a mechanism to facilitate mattress sutures. Bovine thoracic aorta and grafts (20 mm and 26 mm in outer diameter) were used. EPTFE felts were used for the outer side of the aorta. The suture needle was 9.0 mm in length and suture threads with straight stitches were used. [Results]1.Thickness of the aortic wall and the certainty of handing over of the needle : Although the needle was handed over accurately by the anastomotic device up to aortic wall thickness of 4.6 mm, difficulties were encountered in some cases with wall thicknesses of 4.8 mm or more. 2.Distance between adjacent mattress sutures : In the case of 2.0 mm, a space between adjacent mattress sutures was found and leakage from the anastomosis site was found in water infusion test. In the cases of 1.0 mm and of 1.0 mm overlap, no penetrating space was found between adjacent mattress sutures. 3.Inter-needle distance of the anastomotic device : With the inter-needle distance of 5.0 mm, there was no problem in the mechanism of needle handing over and no spaces were found between the mattress sutures. With an inter-needle distance of 7.5 mm, the needle bent and the handing over mechanism was disturbed in some cases due to the aortic curvature face and the hardness of the tissues. When there was no overlap of adjacent mattress sutures, spaces were produced between the mattress sutures themselves. [Conclusions]With an inter-needle distance of 5.0 mm and adjacent mattress suture interval of 1.0 mm, the development of anastomotic device in the present study suggested that a clinically useful anastomotic device could be made in the future.

  • Research Products

    (2 results)

All 2006

All Journal Article (2 results)

  • [Journal Article] 胸部大動脈瘤手術の低侵襲化を目的とした大動脈・人工血管吻合器の考案・作製と実験的検討2006

    • Author(s)
      今牧端蒲
    • Journal Title

      日本外科学会 107・2

      Pages: 521

    • Description
      「研究成果報告書概要(和文)」より
  • [Journal Article] Development of an anastomotic device for distal anastomosis to achieve marked improvement of total arch replacement2006

    • Author(s)
      Mizuho Imamaki
    • Journal Title

      Journal of Japan Surgical Society Vol.107-2

      Pages: 521

    • Description
      「研究成果報告書概要(欧文)」より

URL: 

Published: 2007-12-13  