2016 Fiscal Year Final Research Report
Development of general flow-rate measurement system for various coolants of advanced reactors
Project/Area Number |
16K14531
|
Research Category |
Grant-in-Aid for Challenging Exploratory Research
|
Allocation Type | Multi-year Fund |
Research Field |
Nuclear engineering
|
Research Institution | Hokkaido University |
Principal Investigator |
|
Project Period (FY) |
2016-04-01 – 2017-03-31
|
Keywords | 新型炉 / 革新炉 / 液体金属 / 流速分布計測 / 流量測定 / ガリンスタン / 変換係数 / 流量測定試験 |
Outline of Final Research Achievements |
In order to improve the accuracies of flow-rate measurement in highly-safe liquid-metal cooling reactors as the next-generation innovative nuclear reactor, the flow rate measurement system eliminating the profile factor dependent on the flow velocity profile is made during the research period of this one year. Measurement coolant is selected with the liquid metal called Galinstan, which consists of gallium, indium and tin (Ga / In / Sn). A liquid-metal flow-rate measuring system was fabricated, having the sizes of a height of 1100 mm, a width of 1848 mm, and a depth of 310 mm, in which a horizontal piping test part with a pipe inner diameter of 20 mm was installed. The optimization of the measuring method and the flow-rate measurement have been carried. Future data accumulation will contribute to development of flow-rate measurement system for general and various coolants for advanced reactors.
|
Free Research Field |
原子力システム安全工学
|