Condition based maintenance for blanket cooling pipes by using electromagnetic acoustic technique

Research Project

Project/Area Number 17560731
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Nuclear fusion studies
Research InstitutionOsaka University

Principal Investigator

OHTSUKA Yusuke  Osaka University, Graduate School of Engineering, Assistant Professor, 大学院工学研究科, 助手 (70294048)

Project Period (FY) 2005 – 2006
KeywordsElectromagnetic Acoustic Transducer / Condition Based Maintenance / Cooling Pipe / Fusion / Maintenance
Research Abstract

For the case of the sample thickness longer than the wave length, defects were positioned between a transmitter and a receiver separated by a distance of 200mm. In order to facilitate the propagation of the ultrasonic waves uniformly over the whole inspection region, the propagation angle of the ultrasonic wave was varied by varying the transmission frequency. Next, the waveform from a defect was compared with reference waveform data for the case of no defects. The results showed that the differential signal had a maximum amplitude at 500KHz and 700KHz in the case of defects in the front surface and at 560KHz for defects at the bottom surface. We found that the transmission frequency yielding maximum single amplitude was equal to the propagation direction of the ultrasonic wave.
For the case of the sample thickness nearly same as the wave length, the amplitude of the waves varied with the defect position when the Electromagnetic Acoustic Transducers (EMATs) swept above the defect while keeping the distance between the transmitter and the receiver constant. As a result, the value of the thickness reduction evaluated from the gradient of fitting line was obtained within maximum error of 10 %, for 3mm and 5 mm of the thickness reduction.
In order to obtain high transmission amplitude, new design of achieved EMAT with a magnetism coil was proposed. For all types of the magnetism coils, the current driven EMAT the high amplitude performance. Especially, in the case of two stacked magnetism coils of 1.0 mm in width for the current driven EMAT, the obtained amplitude was 1.8 times as large as that of the magnet type EMAT. This indicates that the ratio of signal to noise would be considerably improved in the high frequency region.

  • Research Products

    (1 results)

All 2006

All Journal Article (1 results)

  • [Journal Article] Fundamental experiment for inspection of cooling pipes in operation by using ultrasonic technique2006

    • Author(s)
      Y.Ohtsuka et al.
    • Journal Title

      Fusion Engineering and Design 81

      Pages: 1583-1587

    • Description
      「研究成果報告書概要(和文)」より

URL: 

Published: 2008-05-27  