2007 Fiscal Year Final Research Report Summary
Study on Piled-Raft Foundation under a Detached House
Project/Area Number |
18360267
|
Research Category |
Grant-in-Aid for Scientific Research (B)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Building structures/materials
|
Research Institution | Hiroshima University |
Principal Investigator |
TOMINAGA Koji Hiroshima University, Graduate School for International Development and Cooperation, Professor (10067720)
|
Co-Investigator(Kenkyū-buntansha) |
WAKAI Akihiko Gunma University, Graduate School of Engireering, Associate Professor (90292622)
|
Project Period (FY) |
2006 – 2007
|
Keywords | Detached house / Steel pipe pile / Timber pile / Piled-raft foundation / Vertical bearing caned / Lateral resistance / Finite element method / Estimation of performance |
Research Abstract |
The purpose of this study is to deal with the structural design of the piled-raft foundation to supporting a detached house constructed on soft ground. The timber piles, which are constructed by the press in method, are used for the piled-raft foundation. Thus, we should propose first the analytical methods for the behaviors of a tapered-pile under the vertical and lateral loads, because that the configuration of the timber pile is almost the tapered shape. In this study, the vertical and lateral loading tests were also performed on the tapered steel pipe piles and timber piles. Furthermore, comparisons were made between the final press-in load and the ultimate load from the vertical loading test From a series of studies, we obtained the lemming as follows: 1. The results calculated by the proposed method for the press-in pile are in fairly agreement with the experimental results. 2. Because that the ultimate bearing capacity from vertical loading tests was lager value than the final press-in loads, it is found out that the strength of soil surrounding the pile was in restoration while curing the 'pile. 3. It is possible for the ultimate bearing capacity of the pile to be estimated from the final press-in load. 4. The results calculated by the proposed method for the laterally loaded tapered pile are in fairly agreement with the test results, and indicate well characteristics that the soil surrounding the tapered pile is hardening by press-in pile. 5. From the results analyzed by the tree finite element method, it is found out that the piles embedded length of 3 m are effective for the piled-raft foundation.
|