2020 Fiscal Year Annual Research Report
Electrical, thermal and structural performance of new membrane building integrated PVs
Project/Area Number |
18F18345
|
Research Institution | The University of Tokyo |
Principal Investigator |
川口 健一 東京大学, 生産技術研究所, 教授 (40234041)
|
Co-Investigator(Kenkyū-buntansha) |
HU JIANHUI 東京大学, 生産技術研究所, 外国人特別研究員
|
Project Period (FY) |
2018-10-12 – 2021-03-31
|
Keywords | Public / Residential building / Retractable membrane / ceiling / Energy / membrane ceiling |
Outline of Annual Research Achievements |
1. Energy consumption of comfort management residential house was investigated in terms of air conditioning, radiant floor and retractable membrane ceiling. Effectiveness of membrane ceilings has been validated and quantified (energy reduction of 22% for air conditioning with/without membrane ceiling). The research results have been presented in Annual Meeting 2019 of Architectural Institute of Japan and submitted to Applied Energy (IF 8.426). 2. Long-term building performance of large-span swimming arena with retractable membrane ceilings has been investigated. The energy performance is analyzed with statistical methods to obtain suitable values for designing and retrofitting similar stadiums. The research results have been published in Energy and Buildings (IF 4.799, 207, 109363).
|
Research Progress Status |
令和2年度が最終年度であるため、記入しない。
|
Strategy for Future Research Activity |
令和2年度が最終年度であるため、記入しない。
|