2009 Fiscal Year Final Research Report

Development of ultra stable high voltage supplies for multi-reflection time-of-flight mass spectrograph

Research Project

  • PDF
Project/Area Number 20740165
Research Category

Grant-in-Aid for Young Scientists (B)

Allocation TypeSingle-year Grants
Research Field Particle/Nuclear/Cosmic ray/Astro physics
Research InstitutionThe Institute of Physical and Chemical Research

Principal Investigator

P.H SCHURY  The Institute of Physical and Chemical Research, 低速RIビーム生成装置開発チーム, 客員研究員 (30462724)

Project Period (FY) 2008 – 2009
Keywords原子質量分析器 / 高精度高圧電源
Research Abstract

For precision mass measurements of unstable nuclei using a multi-reflection time-of-flight mass spectrograph, ultra stable high voltage supplies are the essential prerequisites. We have developed such high voltage supplies using precision 24-bit ADC, low TC resisters and PID feedback system. The long-term stability of the high voltages was as slow as 5 mVrms for 1 kV supplies.

  • Research Products

    (2 results)

All 2009

All Journal Article (1 results) (of which Peer Reviewed: 1 results) Presentation (1 results)

  • [Journal Article] Multi-reflection time-of-flight mass spectrograph for short-lived radioactive isotopes2009

    • Author(s)
      P. Schury, et. al.
    • Journal Title

      Eur. Phys. J. A 42

      Pages: 343-349

    • Peer Reviewed
  • [Presentation] Multi-reflection Time-of-Flight Spectrograph2009

    • Author(s)
      P. Schury, et. al.
    • Organizer
      the 3rd Japan-US Joint Physical Society Annual Meeting
    • Place of Presentation
      Waikoloa, Hawaii, USA
    • Year and Date
      2009-10-15