• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2022 Fiscal Year Research-status Report

Reconstruction of dose distributions using PET images in heavy ion therapy

Research Project

Project/Area Number 20K08066
Research InstitutionNational Institutes for Quantum Science and Technology

Principal Investigator

Mohammadi Akram  国立研究開発法人量子科学技術研究開発機構, 量子医科学研究所 先進核医学基盤研究部, 主任研究員 (10554735)

Project Period (FY) 2020-04-01 – 2024-03-31
Keywordsdose reconstruction / PET image / ion therapy
Outline of Annual Research Achievements

A method for prediction of dose profiles from PET images for 11C and 15O ion beams were developed. The depth dose was measured for both ion beams with mono-energetic and poly-energetic conditions in the carbon therapy facility of the Heavy Ion Medical Accelerator in Chiba (HIMAC). The PET images were obtained for an irradiated polymethyl methacrylate (PMMA) phantom with both beams under the same conditions using a prototype PET system. The results of the mono-energetic beams were used for prediction of the dose profiles for the poly-energetic beams and the predicted dose profiles were in overall good agreement with the measured ones.

Current Status of Research Progress
Current Status of Research Progress

3: Progress in research has been slightly delayed.

Reason

For publication the accuracy and reproducibility of the data are essential. Therefore we are planning to perform more experiments. All experiments should be performed at the carbon therapy facility of the Heavy Ion Medical Accelerator in Chiba (HIMAC) using our prototype PET system and the number of experiments is so limited.

Strategy for Future Research Activity

The development and optimization of the method for prediction of dose profiles are going to be carried out for the measured data of an irradiated PMMA phantom with 12C ion beam and radioactive ion beams of 11C with SOBP.

Causes of Carryover

測定データの精度と再現性を評価するために追加実験をする必要があるが、この実験は量医研のHIMACのマシンタイムを利用して行う必要があり、多くの研究者が共同利用しているため、次の割り当ては来年度となっている。そして、この実験のために科研費予算を使用する必要があるため期間を延長する。

  • Research Products

    (1 results)

All 2022

All Presentation (1 results) (of which Int'l Joint Research: 1 results)

  • [Presentation] PET-based range verification of 11C ion beam with SOBP2022

    • Author(s)
      Akram Mohammadi
    • Organizer
      2022 IEEE NSS MIC RTSD (2022 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room Temperature Semiconductor Detector Conference)
    • Int'l Joint Research

URL: 

Published: 2023-12-25  