2022 Fiscal Year Final Research Report
Development of 1 nm X-ray focusing system
Project/Area Number |
20K20444
|
Project/Area Number (Other) |
19H05523 (2019)
|
Research Category |
Grant-in-Aid for Challenging Research (Pioneering)
|
Allocation Type | Multi-year Fund (2020) Single-year Grants (2019) |
Review Section |
Medium-sized Section 30:Applied physics and engineering and related fields
|
Research Institution | The University of Tokyo |
Principal Investigator |
Mimura Hidekazu 東京大学, 先端科学技術研究センター, 教授 (30362651)
|
Co-Investigator(Kenkyū-buntansha) |
木村 隆志 東京大学, 物性研究所, 准教授 (50531472)
|
Project Period (FY) |
2019-06-28 – 2023-03-31
|
Keywords | X線ミラー / X線集光 |
Outline of Final Research Achievements |
In this research, we introduced the idea of significant reduction in mirror length in X-ray focusing using mirrors, aiming for ultimate focusing down to a size of 1 nm. This was a challenging study. During the research period, we successfully developed a high-precision focusing mirror with a focal length of 2 mm and a mirror length of 2 mm. We also achieved diffraction-limited focusing of 20 nm for 2 keV X-rays at SPring-8, and confirmed that it is possible to focus X-rays below 4 nm theoretically for 10 keV X-rays.
|
Free Research Field |
超精密加工、X線光学
|
Academic Significance and Societal Importance of the Research Achievements |
従来のX線ミラーのミラー長は報告されている中では20mmが最小である。本研究ではその1/10の2mm長のミラーの開発に成功した。光の集光においては焦点距離を短くすることで、理論的に誤差の影響を少なくすることができる。本研究における成果はミラーによるX線の極限集光の道を拓いたといえる。開発したミラーを用いれば、X線顕微鏡のシステムの超小型化も可能であり、多くのX線分析技術の性能向上に寄与することができる。
|