• Search Research Projects
  • Search Researchers
  • How to Use
  1. Back to project page

2023 Fiscal Year Research-status Report

Measurement of the Cooling Effect of a Water Mist Fan on Personal Protection Equipment(PPE) and Work Clothing

Research Project

Project/Area Number 21K04567
Research InstitutionOsaka Metropolitan University

Principal Investigator

Farnham Craig  大阪公立大学, 大学院生活科学研究科, 准教授 (60638245)

Project Period (FY) 2021-04-01 – 2025-03-31
Keywordsmist cooling / heat stroke / worker / PPE / clothing / evaporation
Outline of Annual Research Achievements

Full analysis of the large amount of data from FY2022 was supplemented by more precise experiments in FY2023 using more uniform cloth samples and a level heated surface using parts of the FY2022 thermal mannequin system.
Heat flux and temperature measurements yielded overall heat transfer coefficients for work clothes, both dry and wet, both with and without PPE. Total cooling ranged about 40 to 160 W/m2, depending on body location and distance from fan. Thus the mist fan cooling can provide significant cooling to largely counter metabolic heat generated by people doing light labor.
The extra cooling by wetting and flash evaporation was derived by comparing heat flux from non-mist fan and its overall heat transfer coefficient(h) vs. mist fan heat flux. Temperature measurements are not reliable in mist, so taking wet bulb as lowest possible air temperature, and h from the non-mist fan, the excess heat flux must be due to wetting and flash evaporation. This was about 20 to 75W/m2 extra cooling by flash evaporation beyond that of the cooled air forced convection. Secondary wetting (not from sweat) must be introduced into standard models of human heat exchange and thermal comfort to account for this.

Current Status of Research Progress
Current Status of Research Progress

2: Research has progressed on the whole more than it was originally planned.

Reason

Heat transfer coefficients for work clothes and PPE, both wet and dry were found from a total 18 days of outdoor experiment data, with supplemental small scale experiments in FY2023. Full results are summarized in a paper in submission, under peer review. Remaining FY2023 funds were extended to FY2024 to help pay the Open Access fee.

Publications:
1. Farnham,C.ミストファンの冷却効果に対する作業服と防護服の影響に関する実験 、日本建築学会大会(近畿)2023/9/15
1. Farnham,C. "Measurements of the Effect of Work Clothing and Personal Protective Equipment(PPE) on the Cooling Effect of a Mist Fan" 空気調和・衛生工学会大会(福井)2023/9/06

Strategy for Future Research Activity

The results yielded valuable heat transfer coefficient data which is being incorporated into a CFD model. As this CFD model progresses, it is necessary to compare results to standard human thermal models (2-node model and more complex models) as well as human test subjects.

More detailed research is needed into the transient effect of wetting of clothes, their saturation, drying, and effect on cooling by mist. Modification of standard models to account for wettedness not produced by sweat is needed. Kakenhi funding request on this point was rejected. Looking for other sources.

Measurements of wind speed in mist using the ultrasonic anemometer also yielded sonic temperature data, which is now being investigated as a potential method to much more accurately evaluate mist cooling effects.

Causes of Carryover

Research results currently under submission. Remaining funds to be used to help pay Open Access fee.

  • Research Products

    (2 results)

All 2023

All Presentation (2 results)

  • [Presentation] ミストファンの冷却効果に対する作業服と防護服の影響に関する実験2023

    • Author(s)
      Farnham, Craig
    • Organizer
      日本建築学会大会(近畿)
  • [Presentation] Measurements of the Effect of Work Clothing and Personal Protective Equipment(PPE) on the Cooling Effect of a Mist Fan2023

    • Author(s)
      Farnham, Craig
    • Organizer
      令和5年度空気調和・衛生工学会大会(福井)

URL: 

Published: 2024-12-25  

Information User Guide FAQ News Terms of Use Attribution of KAKENHI