2012 Fiscal Year Final Research Report
Study on Critical Heat Flux Mechanism of Subcooled Water Flow Boiling
Project/Area Number |
22560196
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Single-year Grants |
Section | 一般 |
Research Field |
Thermal engineering
|
Research Institution | Kyoto University |
Principal Investigator |
HATA Koichi 京都大学, エネルギー理工学研究所, 助教 (60115912)
|
Project Period (FY) |
2010 – 2012
|
Keywords | 沸騰限界熱流束 |
Research Abstract |
The steady-state critical heat fluxes (CHFs) in a short SUS304-tube with twisted-tape insert are systematically measured. The SUS304 test tube of inner diameter=6 mm, heated length=59.5 mm, effective length=49.1 mm is used in this work. The SUS304 twisted tapes withtwist ratio=pitch of 180°rotation)/d=2.39, 3.39 and 4.45 are used. The influences of the twisted-tape insert and the swirl velocity on the CHFs are investigated into details and the widely and precisely predictable correlations of the CHFs in the SUS304-tube with twisted-tape insert are given. The correlations can describe the CHFs obtained in this work within -25 to +15 % difference.
|