2012 Fiscal Year Final Research Report

Research on inter-scanner difference and improvement of quantitative analysis for multi-center study inpositron emission tomography.

Research Project

  • PDF
Project/Area Number 22611019
Research Category

Grant-in-Aid for Scientific Research (C)

Allocation TypeSingle-year Grants
Section一般
Research Field Medical Physics/Radiological Technology
Research InstitutionTokyo Metropolitan Geriatric Hospital and Institute of Gerontology

Principal Investigator

ODA Keiichi  地方独立行政法人東京都健康長寿医療センター(東京都健康長寿医療センター研究所), 東京都健康長寿医療センター研究所, 研究員 (70224235)

Co-Investigator(Renkei-kenkyūsha) ISHII Kenji  地方独立行政法人東京都健康長寿医療センター(東京都健康長寿医療センター研究所), 東京都健康長寿医療センター研究所, 研究部長 (10231135)
SAKATA Muneyuki  地方独立行政法人東京都健康長寿医療センター(東京都健康長寿医療センター研究所), 東京都健康長寿医療センター研究所, 研究員 (00403329)
KIMURA Yuichi  独立行政法人放射線医学総合研究所, 分子イメージング研究センター, チームリーダ (60205002)
NISHIO Tomoyuki  財団法人先端医療振興財団, 先端医療センター研究所, 研究員 (20470205)
Project Period (FY) 2010 – 2012
KeywordsPET / PET/CT / 定量測定 / 装置関差 / マルチセンター
Research Abstract

We showed scanner dependence of brain 18F-FDG and 11C-PiB images by using phantom examination with nine kinds of PET scanners. We used two types of phantoms, cylindrical phantom with 15cm inside diameter and three-dimensional brain phantom, and we set the body phantom on the bed to examine the effect of scatter and random coefficients from outside of the axial field of view (AFOV). Radioactivity and distance of the two phantoms were determined by a pilot study to obtain a condition similar to clinical study. Axial uniformity was evaluated by circular region of interest (ROI) of 12cm diameter, set in the center of the reconstruction image of the cylindrical phantom. As a result, the standardized uptake value (SUV) was lower than the true value in some scanners, and there was a scanner in which the axial uniformity was deteriorated by high radioactivity outside the AFOV. In the cylindrical phantom, the axial uniformity of the scanner was improved using the new dead-time correction method; however, it was not improved in the 3D brain phantom. Quality-controlled PET scanners are important to maintain constant levels for multicenter studies.

  • Research Products

    (2 results)

All 2012 2011

All Journal Article (1 results) (of which Peer Reviewed: 1 results) Presentation (1 results)

  • [Journal Article] 脳PETにおける装置差に関する基礎的研究2012

    • Author(s)
      織田圭一、坂田宗之、西尾知之、對間博之、谷崎靖夫、加藤誠二、越智伸司
    • Journal Title

      日本放射線技術学会雑誌

      Volume: 68巻 Pages: 669-679

    • DOI

      DOI:10.6009/jjrt.2012_JSRT_68.6.669

    • Peer Reviewed
  • [Presentation] 脳FDG-PETにおける装置間差補正に関する研究2011

    • Author(s)
      織田圭一、對間博之、谷崎靖夫、加藤誠二、越智伸司、西尾知之、坂田宗之
    • Organizer
      第39回日本放射線技術学秋季学術大会
    • Place of Presentation
      神戸国際会議場(神戸市)
    • Year and Date
      20111028-30