2011 Fiscal Year Final Research Report
PLASTIC DEFORMATION CAPACITY OF A BEAM IN CIRCULAR CFT COLUMN-H SHAPED BEAM CONNECTION CONSIDERING COMPOSITE EFFECT BY FLOOR SLABS
Project/Area Number |
22760423
|
Research Category |
Grant-in-Aid for Young Scientists (B)
|
Allocation Type | Single-year Grants |
Research Field |
Building structures/materials
|
Research Institution | The University of Kitakyushu |
Principal Investigator |
KIDO Masae 北九州市立大学, 国際環境工学部, 講師 (10453226)
|
Project Period (FY) |
2010 – 2011
|
Keywords | 鋼構造 / 耐震設計 / 柱梁接合部 / 鋼・コンクリート合成構造 |
Research Abstract |
Loading test of circular CFT column-H shaped beam connection was carried out. Test parameters are diameter thickness ratio of column skin plate, presence or absence of infilled concrete, scallops and floor slabs. The effect of test parameters on maximum strengths was not remarkable when there were not slabs. On the other hand, for test specimen with floor slabs, the maximum load of specimen with non-scallops is 50kN greater than that of specimen with scallops. The effect of out-of-plane deformation is larger in the specimen with scallops considering that the yield area of beam web subjected to tensile stress is smaller and the strain of the column skin plate is larger.
|