2013 Fiscal Year Final Research Report
Development of residual gas ionization beam current monitor for high-intensity DC beams
Project/Area Number |
23540357
|
Research Category |
Grant-in-Aid for Scientific Research (C)
|
Allocation Type | Multi-year Fund |
Section | 一般 |
Research Field |
Particle/Nuclear/Cosmic ray/Astro physics
|
Research Institution | High Energy Accelerator Research Organization |
Principal Investigator |
SATO Yoshinori 大学共同利用機関法人高エネルギー加速器研究機構, 素粒子原子核研究所, 准教授 (30342603)
|
Project Period (FY) |
2011 – 2013
|
Keywords | ビーム強度モニタ / 非接触測定 |
Research Abstract |
We have developed a residual gas ionization beam current monitor (RGICM), which can monitor intense semi-DC proton beams at J-PARC Hadron Experimental Facility with non-destructive feature and less than 10 % accuracy. A prototype RGICM has been tested with 50 MeV proton beam at Research Center for Nuclear Physics, Osaka University, and showed good linearity of less than 7%. The prototype monitor has been installed in the proton beam line at J-PARC Hadron Experimental Facility, and tested with 30 GeV proton beams. The relative stability of the monitor with 30 GeV proton beams was less than 10%. The results indicate that the residual gas ionization profile monitor is useful for semi-DC proton beams at J-PARC.
|
Research Products